SD1200 - Sectional Garage Door Opener
Page 10
Installation & Operating Instructions
V2.09/19
Safety Reversal Force Adjustment
The force, as measured at the bottom of the door, should not exceed 400N (40kgf). If this force is
exceeded safety beams must be installed.
STEP 1. ADJUSTING THE OPEN FORCE
1)
Hold down “P” button for 6 seconds
(LED 2 will begin flashing)
2)
Press the “P” button twice
(LED 6 will begin flashing)
3)
Press and release the “+” button to increase the force or “
−
“ button to decrease the force to the
desired setting
(the numbers 1 to 8 indicate lowest to highest force setting)
4)
Press the “P” button once to save
(LED 1 will begin flashing to indicate the open force is now
programmed and you are ready to adjust the close force)
STEP 2. ADJUSTING THE CLOSE FORCE
1)
Press
and release the “+” button to increase the force or “
−
“ button to decrease the force to the
desired setting
(the numbers 1 to 8 indicate lowest to highest force setting)
2)
Press the “P” button once to save
(LED 3 will remain on indicating the close force is now
programmed)
ener
▪
CAUTION
- Force settings are
automatically
set during the programming phase,
after travel limit setting procedure on pages 8-9.
▪
Too much force will cause improper operation of the safety reversal mechanism and
may cause serious injury. The higher the force is set the less sensitive the opener is
to detecting an obstruction.
▪
Force settings should only be adjusted by a suitable qualified technician.
OPENER FORCE IS NOW SET
The safety reversal system must now be tested by placing a 40mm high
object on the floor and ensuring the door reverses on contact, see page 9.
Adjust force again if necessary.