29
742.110 | 14.50
EN
Display
Characteristic
min.
max.
Factory
setting
Activation
on
,
oFF
oFF
Filling time
1 ... 10 minutes
3 minutes
Stabilising time
1 ... 15 minutes
2 minutes
Draining time:
1 ... 30 minutes
5 minutes
Short startup time
0 ... 60 seconds
0 seconds
10.3.2 Holiday – recooling
Attempts to reduce, or even to avoid, the system standstill (stagnation)
times at high temperatures. To do this, at night the storage tank is dis-
charged as far as possible to the set minimum temperature, if the stor-
age tank temperature during the day was 20 F below the set maximum
temperature.
Stagnation occurs when not enough hot water is removed from the
system during an absence (holiday).
Notes
The following applies to this function:
•
Only activate if you intend to be absent for an extended period.
•
Deactivate this after returning from a holiday in order to avoid an
unnecessary waste of energy via the collector circuit.
•
This function cannot be activated in systems with swimming pools.
•
This function cannot be active at the same time as the drainback
function.
Display
Characteristic
min.
max.
Factory
setting
Activation
on
,
oFF
oFF
Minimum storage tank temperature
32 °F
200 °F
95 °F
Summary of Contents for TR-A501T-U
Page 47: ...47 742 110 14 50 EN 18 Notes ...
Page 48: ...48 742 110 14 50 EN 742110 ...