INST

ALLA

TION & USER GUIDE

LED LIGHT

FUNCTIONS

OPERATIONAL APPROACH

BLUETOOTH

STEAM

CHROMA LIGHT

1

.

 START-UP/SWITCH OFF

 

POWER ON 

START-UP

The control panel will BEEP when it’s connected to a power source.

When the system is under stand-by mode, press the         key to start-up. The current 

ambient temperature in the room and bluetooth music icon will be displayed on the 

screen as shown in Figure 1. After the interface is fully displayed, press the function 

key on the screen to unlock. 

If a user has set the a scheduled start up function, when the secduled time arrives, the

system will start-up automatically and begin the process of producing steam.

Press the        key to power down the control panel and enter standby mode. During this

mode the clock will be displayed on screen.

The system will power-off automatically when the pre-set time is reached. (The 

system will be shut down after 2 minutes of the steam function closed.)

POWRE

-

OFF

2

.

Control of White LED Light (If Equipped)

After power-on, the lighting section interface is shown in Figure 4 as follows: Press 

    

 

to turn on the light ; Press 

    

to turn off the light. 

3.Control of Color Changing Light (If Equipped)

 

When the system is power-on, enter in the lighting interface as shown in Figure 4: 

Press 

    

key to turn on the Color-Changing light, and then press 

       

key to 

change the color of the light. Press the       key to turn off  the Colored-light Function 

after the color-changing light function is started.

Summary of Contents for S 1050

Page 1: ...4 5KW 6KW 7 5KW 9KW 10 5KW 12KW MODELS BLACK SERIES V2 1 Steam Spa PHONE 800 856 0172 FAX 866 560 1060 http steamspa com info steamspa com W HIS P E R QUI E T B U I L T IN A UTO D R A I N C O N TIN U O U S ST E A M Q UIC K S TAR T ...

Page 2: ...Steam Spa PHONE 800 856 0172 FAX 866 560 1060 http steamspa com info steamspa com ...

Page 3: ... 10 ELECTRICALREQUIREMENTS 11 ASSEMBLYGRAPH FORPOWERWIRE 12 INSTALLATIONOFTHE TOP LIGHT 14 STEAM GENERATORDISSECTIONDIAGRAM 15 CARE USEFORTHE CONTROL PANEL 16 CONTROLLERBOXCONTENT 16 CONTROLPANELINSTALLATIONINSTRUCTIONS 17 TESTINGTHEMACHINE 18 CONTROLPANELDIAGRAM 18 CONTROLPANELOPERATION 19 STEAM GENERATORMAINTENANCE 25 TECHNICALPARAMETERS 29 WIRINGDIAGRAMS 30 IMPORTANT PRIORTOINSTALLATION LET WAT...

Page 4: ...omer ServiceDept within48hoursofdelivery 3 Read installation instructionsindetailforasecureandeffectiveinstallationofSteamSpagenerators 4 SteamSparecommendstheuseofalicensedplumberandelectricianforproperinstallationofSteamSpagenerators 5 SteamSpashallnotberesponsibleforproductdamageormalfunctioncausedbyself installationorinstallation procedures which do not complywithusermanual 6 SteamSpagenerator...

Page 5: ...0 http steamspa com info steamspa com Page 5 INSTALLATION USER GUIDE INSTALLATIONDRAWINGOFSTEAMGENERATOR ATTENTION Thedrawingisonlyforexplanationpurposes Asforpracticaldesignofsteam room pleaseconsult withaqualified designer architect or builder ...

Page 6: ...0 http steamspa com info steamspa com Page 6 INSTALLATION USER GUIDE ATTENTION Thedrawingisonlyforexplanationpurposes pleaseconsultwithaqualifieddesigner architectorbuilder IMPORTANT Allpipeconnectionsshouldhaveunionsandadaptersforeasydisconnect ...

Page 7: ...mustcomplywiththenation selectricalcriteria andbe done byaprofessionalelectrician Thesteam generator maybeinstalledintheselocation 1 Incloset located behindtheshower 2 InAttic 3 Inbasement etc ATTENTION If theinstallationofthesteamgeneratorwillbemorethen10to15feetawayfromthesteamroom Itis recommended to increasethesizeofthegenerator1or2kilowattshighertoincreasethesteamflow 110 ...

Page 8: ...llanystopvalvesinthesteampipes Thesteamcanneverbeobstructed 2 Installa copperpipebetweenthesteamgeneratorandthesteamnozzleforallgenerators exceptthe4 5KWwhich requiresa copperpipe 3 Ifneeded theheatinsulationmaterialusedtoinsulatethesteampipeshouldberesistanttotemperaturesashighas240For higher 4 Theshorter thedistance thebetter Usecurvedelbowswhenconnectingpipestoallowthesteamtoflowsmoothlythrough...

Page 9: ...afety valveor steam linetodrainline SAFETYVALVE 3 4 1 Safetyvalveisanautomaticsystemthatisactuatedbypressureinordertopreventsteampressureincreasingintheinterior ofthegenerator 2 Thepressurelimitrangeofthesafetyvalveis15PSIGandthepressurewillbegintodecreaseifpressureshouldcomeover thisvalue 3 Ifit isallowed bylocalcodes providethesafetyvalvewithexteriordrainpipe 4 Do not dismantlethepressurereliefv...

Page 10: ...nage 206mm 188mm 151mm 32mm 43mm 142mm 266mm 302mm 395mm Fuse for wire power supply Power wire hole C ontr olle r w ir e and light wire hole 304mm 400mm 160m m 100m m 30mm 30mm 1 8 0 mm 2 6 0m m 3 7 0 mm Steam outlet S a f e t y valve Water inlet Water drainage Fuse for wire power supply Power wire hole C o n tro ller wire an d lig h t wir e hole Fuse for wire power supply Fuse for wire power supp...

Page 11: ...mgenerator 2 Insulated copper wireshouldbeusedwithananti heattemperatureof90Candaspecifiedvoltageof300V Refertonational orlocalelectricityconsumptioncodeforthespecifications Refertotheammeterfortheampere 3 Connect suitablysizedequipment groundingwireintothegroundterminal 4 All theconnectionsmustbeinaccordancewithnationalandlocalelectricityconsumptioncodesandbeinstalledby professional electricians ...

Page 12: ...ipment donotconnectelectriccurrentdirectlytoheatingelements WARNING Thisgraphisforexplanationonly Foractualinstallation refertonationaland localelectricityconsumptioncodesby professional electricians Ampere Meter Ty p e Power KW S600 S750 6 7 5 9 240V 240V 240V 25 32 38 10 8 8 150 225 300 Applicable space of the room cu Ft El e c t r i c i t y supply 1PH E l e c t r i c current A Specifications fo...

Page 13: ...ll water valve Drai n water valve Term inal B lock J1 1 J2 1 J3 1 J3 2 J2 2 J1 2 J1 J2 J3 S S G Yellow Green R ed B lack Red Black White Black Yellow R ed B lack Red Red Red Red Su p p ly R ed B lack Red Black L1 L2 Water Level Sensor Red S h o r t P i n Bl ack Lo n g P i n Yel l o w Mi d d l e P i n Red Red Red Red Red Black Black Black Black Black Blac k Red Black J1 1 J1 2 J1 S S L1 G S450 Su p...

Page 14: ...1 L2 Water Level Sensor Red S h o r t P i n Bl ack Lo n g P i n Yel l o w Mi d d l e P i n Red Red Red S750 S900 Red Red Black Black Black Black Black Blac k Red Black To C ontrol P anel Fill water valve Drain water valve Term inal B lock J1 1 J2 1 J2 2 J1 2 J1 J2 S S G Yellow Green R ed B lack Re d Black White Bla c k Yellow R ed B lack Red Red Red Red Su p p ly R ed B lack Black L1 Water Level S...

Page 15: ...IONDIAGRAM 1 2 3 4 6 5 7 13 14 12 9 11 8 10 15 17 16 1 ENCLOSURE 2 INSULATIONBRACKET 3 CIRCUITBOARD 4 STEAM OUTLET 5 PRESSURERELIEF VALVE 6 WATERFILLVALVE 7 WATERDRAINVALVE 8 SUBSIDIARYWATERTANK 9 MAINWATERTANK 10 HEATINGELEMENT 11 221FHI LIMIT 12 TRANSFORMER 13 TERMINALBLOCK 14 FUSE 15 GROUNDWIRECONNECTOR 16 RELAY 17 WATERLEVELSENSOR ...

Page 16: ...ation Donot installSteamSpacontrolswithotherthanSteamSpacompatiblesteamgenerators Doingsomayresultinpossible generator damageor inoperativeinstallation SingleControl PanelwithTemperaturesensormustbeinstalledinsidebathingarea5feetabovefloor Donotinstall Control directlyaboveSteam Headorbelowshowerheadbutratherintheseatingareaonaverticalwall Doingsomayresultinimproper temperaturereading and orinoper...

Page 17: ... Page 17 INSTALLATION USER GUIDE 1 7 WITH EXTENSION RIM NO EXTENSION RIM 0 0 92 INCH INCH 0 89 I NCH 4 37 I NCH 4 78 INCH 4 41 INCH 4 INCH 3 20 INCH 3 10 INCH 2 07 INCH 5 54 INCH 1 70 INCH 0 92 INCH 0 31 INCH 5 54 INCH 4 41 INCH 4 INCH 4 37 I NCH 3 20 INCH 3 10 INCH CONTROLLERSPECS ...

Page 18: ... ground Open a hole as shown above Make it 47 to 50 inches from the ground A Recess mount onto the wall using the control box B Recess mount with mounting plate C Using the double sided adhesive Place control box into the hole Insert screws to hold control box in place Fix the control panel to the control box Add a bead of silicone around the edge to seal Fix the control panel to the mounting plat...

Page 19: ...em will start up automatically and begin the process of producing steam Press the key to power down the control panel and enter standby mode During this mode the clock will be displayed on screen The system will power off automatically when the pre set time is reached The system will be shut down after 2 minutes of the steam function closed POWRE OFF 2 Control of White LED Light If Equipped After ...

Page 20: ...ter the interface shown in Figure 7 to set relative parameters Time setting Stop the cursor on the desired Timing by using the or key set hours by pressing key and minutes by key The parameters are set in loop with 1 hour increments and a range of 0 23 hours And a 10 minute increments and a range of 0 50 minutes Working mode Move the cursor from Sunday to Monday bar with key Then select the functi...

Page 21: ...wer on and press OK key to enter the interface shown in Figure 8 Move the cursor to the parameters need to be set by pressing key e g Hour minute date month year displaying time or not after power off etc Then adjust the parameters by pressing key The parameter of week will be calculated automatically by date input system Press the OK key to save the parameters set Exit the interface by pressing E...

Page 22: ... is going to be restarted after 10 seconds the bluetooth shall be connected through the cell phone then start the music player to play the music The bluetooth can be operated normally only after the synchronous success The bluetooth equipment was named as sauna 5 The bluetooth status indicating icon will be flash on the bluetooth interface when the bluetooth equipment is not connected then otherwi...

Page 23: ...uscomponentscannotbe exposed to moisture asitwillcausedamagetothelightcomponentscausing apossibleshortcircuit INSTALLINGSPEAKERS 1 Choseaproper placeonceilinginsidethesteamroom 2 Open 4 holeswith5mmdepthand100mmdiameter 3 Fixthespeaker andgrillontheceilingwiththeprovidedscrewsaspictured 4 5 mm Rubber Gasket Tighten Nut LED light Ceiling of steam room speaker grill ceiling screw speaker 90 90 Ø4 58...

Page 24: ...inthecontrolpanelwillrisewiththetemperatureintheroombeforeitstopsandstaysattheset temperature 5 Based on differentrequirementsoftheuserfortemperatureandsteamtime thecontrolpanelcanadjusttemperatureand steam time 6 When theset steamtimeisdue thesystemwillshutoffthesteamandlightfunctionautomaticallytostopwaterinputand steam production 7 30minutesafter thesteamisshutoff thesystemwillstartdrainageauto...

Page 25: ...60 http steamspa com info steamspa com Page 25 INSTALLATION USER GUIDE 110 0 110 figure1 main screen figure 2 clock screen figure 3 bluetooth screen figure 3 light screen figure 4 user presents figure 5 se ngs Min 110 0Min 110 0Min 110 0Min 110 0Min ...

Page 26: ...SteamSpa PHONE 800 856 0172 FAX 866 560 1060 http steamspa com info steamspa com Page 26 INSTALLATION USER GUIDE figure 7 schedule screen figure 8 clock se ngs figure 9 temp se ngs figure 10 presents mode ...

Page 27: ... 2 Thereshould not beanyleakageordamageamongthesteamgenerator steamnozzle componentsandpipes Theyshould be checked and repairedannually 3 Clean thewater supplypipesofthesteamgeneratoronceayear 4 Checkallthepipeconnections toensurewethertheyaretightandnotdamagedduetooverheat 5 Itisrecommendedthatthewatersensorpronggetscleanonceeverysixmonth 1 Removethecasingofthegenerator 2 Locatethewater sensor 3 ...

Page 28: ...motherboard Water leakage 1 Thewaterpipeconnectorbecomes looseorpipeisbroken 2 Waterleakageinthewaterinput valveorthewaterdrainagevalve 1 Tightenthelooseconnectionor changethebrokenpipe 2 Changethewaterinput valveorthe waterdrainagevalve Nosteam when startingthemachine 1 Noelectricity 2 Nowater 3 Thesettemperatureistoolow 4 Wiringconnectionproblem 1 Checkthepowersupplyand connections 2 Checkthewat...

Page 29: ...12V 3W 12V 3W 12V 3W 12V 3W 12V 3W 12V 3W 12V 3W TimeSet Range min 1 60 1 60 1 60 1 60 1 60 1 60 1 60 SteamPress psi 3 4 4 4 5 5 5 SteamVol cu in min 9 11 13 16 19 21 25 SteamSprayTime sec 100 180 180 240 150 210 120 180 170 230 150 160 120 150 Water Vol cu in 80 160 160 160 330 330 330 ApplicableSpaceof the Room cu ft 90 150 225 300 400 450 500 IMPORTANT Thelist aboveisforreferenceonly Actualchec...

Page 30: ...ethatthegeneratorisconnected240velectricalsupply DAMAGED 1FT CONTROLCABLE Havecustomercheckthepinsatthemaleconnectioncomingfromthebackofthe generator If pinslooktobeokay removelidtoseeifconnectionmadeatterminalblockisloose Ifsopressconnectionin completely DAMAGED CONTROLLEREXTENSIONCABLE Lookatthemaleandfemaleendofthe20ftextension Checkifthereis visibledamagetothepinsandconnection orifanypinsaremi...

Page 31: ...erthantherequired sizedecreaseuntilyouareattherecommendedgaugeorlower CONTROLPANELON WITHNOFUNCTION CONTROL CABLEPINSBROKEN Confirmthatthecableconnectionsareintactandnopinsaremissingfromthe generator to extensionconnectionortheextensiontocontrolpanelextension CONTROL CABLECONNECTIONISLOOSE Confirmthatcontrolcableconnectionsaretightlymadebypressingtogether firmlyat xyzconnections LOOSE RELAYCONNECT...

Page 32: ...STEAMBATHGENERATORUSERGUIDE Steam Spa PHONE 800 856 0172 FAX 866 560 1060 http steamspa com info steamspa com W HIS P E R QUI E T B U I L T IN A UTO D R A I N C O N TIN U O U S ST E A M Q UIC K S TAR T ...

Reviews: