STEAMAX SINUOUS FJ200 – ERROR MESSAGES & PROTECTIONS
Low Atomizer Protection
Atomizer Protection & No Atomizer
Temperature Protection
Device too hot
Weak Battery
Charge Batteries
If the resistance of the coil is lower than 0.1 ohm in VW mode or 0.05 ohm in TC or TCR mode, the display shows
“ATOMIZER LOW”.
If an voltage surge occurs at the atomizer, the unit will display
“ATOMIZER SHORT”.
The display will read
“NO ATOMIZER FOUND”
when
there is no atomizer connected.
If the temperature of the atomizer coil is above the temperature you set, the device will display
“TEMP PROTECT”.
You can continue to
use the device normally.
When the temperature of the device becomes too hot, the power turns off and the display will read
“DEVICE TOO HOT”
. You will be able
to use the device once it has cooled down.
When the power output of the batteries drops below 2.9 V, the display will read
“WEAK BATTERY”.
The output power will be reduced to
match the voltage output of the batteries.
If the power of battery is lower than 10%, the power symbol will flash on the screen.