D2272-02-05 CN5219 SEM310  WEB User Guide 

* Resistance Range, (10 to 390) 

 (End to End) Larger values can be accommodated by fitting 390 

 

resistor (not supplied) as shown below. 
 

(Refer to Fig 2 connection diagram for SEM310X) 

 
Fig 4 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Page 7 

 

 

ALSO AVAILABLE: 

 

 

Smart In Head Temperature Transmitters 

 

Din Rail Mounted Temperature Transmitters 

 

Panel & Field Temperature Indicators 

 

Temperature Probes 

 

Trip Amplifiers 

 

Signal Conditioners 

 

And many other products 

 
 
 
 
 
 
For further information on all products: 
 
 
 
 
 
 
 
 
 

Status Instruments Ltd, Status Business Park, Tewkesbury, Glos. GL20 8FD 

 Tel: +44 (0)1684 296818       Fax: +44 (0)1684 293746 

Email: [email protected]       Web: www.status.co.uk 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Page 8 

2

1

1

Pt100

4

5

6

HART

Temp.

Tx

(4 to 20) mA

+

T/C

2

3

- +

-

Power

Supply

Load

3

4

5

6

Pt100

3

3

3

4

6

4

4

(10 to 40) VDC

mV

Thermocouple

Millivolt

Slidewire

Pt100 2 wire

connection

Pt100 3 wire

connection

3

4

6

3

6

390  

(4 to 20) mA

+

-

+

-

+

-

Pt100 4 wire

connection

Pt100

Pt100

See Note 

5

 

Summary of Contents for SEM310

Page 1: ...RATURE TRANSMITTER Status Instruments Ltd Status Business Park Tewkesbury Glos GL20 8FD Tel 44 0 1684 296818 Fax 44 0 1684 293746 Email sales status co uk Web www status co uk INDEX SECTION CONTENTS PAGE NO 1 0 DESCRIPTION 1 2 0 SPECIFICATION 1 5 3 0 INSTALLATION 6 7 ...

Page 2: ...L 100 to 600 25 TC Type N 180 to 1300 50 TC Type X 3 User defined Linearisation BS EN60584 01 BS 4937 IEC 584 1 multi segment Polynomials Basic Measurement Accuracy 2 0 04 FRI 0 04 RDG or 0 5 C whichever is greater Thermal Drift Span 0 01 C Cold Junction Error 0 5 C Cold Junction Tracking 0 05 C C Cold Junction Range 40 to 85 C Page1 2 3 MILLIVOLT INPUT Input Voltage Source Range 10 to 75 mV Chara...

Page 3: ...to identify the equipment as suitable for Hazardous area use The equipment must be installed and maintained in accordance with local requirements for electrical equipment for use in potentially explosive atmospheres eg EN60079 14 EN60079 17 This instruction sheet describes installation which conforms with BS EN60079 14 BS EN60079 17 Electrical Installation in Hazardous Areas When designing systems...

Page 4: ...r body direct to the input screw terminals The screw terminals have been designed to allow all connection wires to enter from an inner or an outer direction Care must be taken when locating the transmitter to ensure the ambient temperature remains within the specified operating range Fig 3 All Dimensions in mm 3 2 ELECTRICAL Connections to the transmitter are made to the screw terminals provided o...

Page 5: ...ators Temperature Probes Trip Amplifiers Signal Conditioners And many other products For further information on all products Status Instruments Ltd Status Business Park Tewkesbury Glos GL20 8FD Tel 44 0 1684 296818 Fax 44 0 1684 293746 Email sales status co uk Web www status co uk Page 8 2 1 1 Pt100 4 5 6 HART Temp Tx 4 to 20 mA T C 2 3 Power Supply Load 3 4 5 6 Pt100 3 3 3 4 6 4 4 10 to 40 VDC mV...

Reviews: