10
Important: For butane/propane gas, the adjusting screw must be tightly screwed in.
• Refit the control knobs to each Gas Tap.
• Test the flame by quickly turning the Control Knob from maximum to minimum, if the flame goes
out then you will need to make further adjustments to the gas flow.
• Repeat the process again until the gas flow is correct.
WARNING: Do not dismantle the Gas Tap Shaft: In the event of a malfunction, change the
whole tap.
• Before replacing the Flame Spreader and Burner Cap, ensure that the Injector is not blocked.
• A full operational test and a test for possible leaks must be carried out after a gas conversion.
• After completing conversion, the quailified gas engineer will need to mark “V” on the right gas
category to match with the setting on the rating plate. Remove the previous setting mark.
Injector
Control handle
Sealing ring
Tap
Change the Injector of the Burners
• Remove the pan support, burner lid and flame spreader.
• Unscrew the injector using a 7mm box spanner and replace with
new injector correct for the new gas supply. Ensuring that the new
injector is firmly tightened.
• Carefully reassemble all the Burner Cap, Burner Crown and Flame
Spreader.
Adjustment of Minimum Level of the Flame
• Ignite the burner and set to MIN
• Remove the Control Knob and place a small bladed screwdriver in
the centre of the Gas Tap Shaft.
• Adjust until a steady flame is reached, about 3 – 4mm and does
not extinguish when the Control Knob is turned down to MIN.
• Repeat this procedure for all burners.