S U F S E R V I C E H A N D B O O K
C O M P O N E N T I N F O R M A T I O N
Technical Training Department
State Water Heaters
STC-077
32
Ashland City, Tennessee © 2004
COMPONENT INFORMATION
ORIFICE TABLE
* -4 and -5 stamped with “P” for Propane
N O T E :
Hex head of main burner orifice is upstream end — gas flows out of tapered end.
FLAME SENSING ROD
PART NUMBER
FLAME SENSING CURRENT
COMMENTS
192478
0.7 Micro Amp (µ)
SUF 150, 199, & 240
HOT SURFACE IGNITOR (HSI)
PART NUMBER
VOLTAGE
AMP
OHMS COLD
COMMENTS
192638
120 VAC
1.0
50 – 300
SUF 150, 199, & 240
ORIFICE TABLE
SUF MODEL
MAIN BURNER
ORIFICE NO.
MAIN ORIFICE SIZE
INCHES
AIR ORIFICES
PT. NO.
AIR ORIFICE
SIZE — INCHES
150
192477-1
0.235
192450-1
0.875
199
192477-0
0.304
192450-0
1.031
240
192477-2
0.360
192450-2
1.196
150 Prop
192477-5
0.141”
192450-5*
0.872
199 Prop
192477-4
0.166”
192450-4*
1.150