Convert to another category of gas
Release R.1.0 Uk
33
is
5. Connect the supply cable to the main switch.
Warning
Leave the appliance disconnected until you are ready to put it into operation.
3.10.4
Week timer circuit
1. Cut out the week timer image from the control panel.
2. Fit the week timer in the hole.
3. Connect the week timer by connecting the wires with core bush to 7 (N), 9
(L) and 11 (L).
4. Connect the cable with sliding bush to position B4 of the
I/0/II
-switch.
5. If you do not need to make any more connections, then fit the protective cap
on the control column.
3.10.5
Extra fault sensor ('Fault output')
Fault OUTPUT is a potential-free contact that is switched in case of a fault.
Objects (e.g. one or more LEDs) can be connected to this in order to indicate
the fault (max. 250V, 10A).
The object(s) can be both connected in a circuit with a make contact (LED is
on in case of a fault) and in a circuit with a break (LED is on during normal
use).
1. Feed the extra indicator cable through the metric pull relief on the top of the
control column.
2. Connect the extra indicator at points 13 (NO) and 14 (P), and/or 14 (P) and
3. Tighten the pull relief so that the cable is jammed.
4. If you do not need to make any more connections, then fit the protective cap
on the control column.
3.11 Convert to another
category of gas
c
Note
The conversion may only by carried out by an approved installer.
Summary of Contents for SCE 65-400
Page 2: ...your installer ...
Page 4: ...4 SCE Instruction Manual ...
Page 8: ...8 Instruction Manual SCE gis ...
Page 12: ...Introduction 12 Instruction Manual SCE 1 gis ...
Page 18: ...Operating the appliance 18 Instruction Manual SCE 2 gis ...
Page 42: ...Installation 42 Instruction Manual SCE 3 is ...
Page 46: ...Filling and draining 46 Instruction Manual SCE 4 gis ...
Page 64: ...Maintenance 64 Instruction Manual SCE 9 s ...