![State Water Heaters 110C Installation Manual And Owner'S Manual Download Page 4](http://html.mh-extra.com/html/state-water-heaters/110c/110c_installation-manual-and-owners-manual_1366794004.webp)
4
Page
Model
110C
310C
510C
Natural Gas Input
(Operating Range)
BTU/h
Min.: 15,000
Max.: 140,000
Min.: 15,000
Max.: 190,000
Min.: 15,000
Max.: 199,000
Gas Connection
3/4" NPT
Water Connections
3/4" NPT
Water Pressure*
psi
(Mpa)
15 - 150 (0.1 - 1)
Natural gas
Inlet Pressure
" W.C.
(kPa)
Min. 5.0 (1.24)
Max. 10.5 (2.61)
Weight
lbs. (kg)
51 (23)
Dimensions
inch
H 20.5 x W 13.7 x D 10.5
H 520 x W 350 x D 266
mm
Ignition
Electric Ignition
Electric
Supply
VAC / Hz
120 / 60
Consump
tion
Operation
W / A
53 / 0.58
71 / 0.81
72 / 0.85
Standby
W / A
2 / 0.06
2 / 0.06
3 / 0.07
Freeze-
Protection
W / A
99 / 0.83
99 / 0.83
100 / 0.83
SPECIFICATIONS
*Maximum flow may need water pressure equal to or above 40 psi.
NOTE:
• Check the rating plate to ensure this product matches your specifications.
• In accordance with ANSI Z21.10.3, CO emission does not exceed 400 PPM for normal input.
•
The manufacturer reserves the right to discontinue, or change at any time, specifications or designs
without notice and without incurring obligations.
Specifications
Installation Manual