3. Crimp the
"Fork terminals"
to the cable.
(Fig. C)
4. Tighten the two
"Fork terminals"
beneath the two
"Remote controller terminal"
screws on the back of
the main body.
(Fig. D-1)
5. Cut out the inlet for the remote controller cable
from the bottom of the main body.
(Fig. D-2)
6. Place the
"Main body"
back on the
"Back plate"
,
with the
"Remote controller cable"
running out of
the bottom inlet.
Remote controller
terminals
Fig. D-1
Two fork terminals
Remote controller cable
Inlet for the remote
controller cable
Cut out
Fig. D-2
<How to connect the remote controller to the water heater>
1. Disconnect power supply from the water heater.
2. Take off the water heater’s front cover.
3. Locate the two terminals for the remote controller in the water heater. (Refer to the Fig. E-1 and E-2.)
4. Put the remote controller cable through the hole at the bottom of the casing of water heater from
outside.
5. Properly connect the two terminals attached to the end of the remote control wires to the terminals
for the remote controller on or near the computer board with the screws. (No polarity)
* Do NOT jump or short-circuit the wires, or the computer will be damaged.
6. Replace the water heater's front cover securely.
Installation
Installation Manual
Fig. E-1
110C and
310C models
9009069005
(TM-RE42)
Connect other end to these terminals
510C model
9009069005
(TM-RE42)
Connect other end to these terminals
Fig. E-2
Remote controller cable
1-3/8 Inch
(35 mm)
Fig. C
1-5/8 Inch
(41 mm)
Fork
Terminals
Wires used for the remote controller connection must be:
•
Minimum 20
gauge wire (No polarity)
•
Maximum 400 ft. (122 m) long