background image

Musikhaus Thomann · Treppendorf 30 · 96138 Burgebrach · Germany · www.thomann.de

Summary of Contents for GF-3000

Page 1: ...GF 3000 Ground Fog Machine user manual...

Page 2: ...Musikhaus Thomann Treppendorf 30 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 20 04 2015 ID 358342...

Page 3: ...conventions 6 1 3 Symbols and signal words 7 2 Safety instructions 9 3 Features 15 4 Installation 16 5 Connections and operating elements 17 6 Operating 19 7 Technical specifications 22 8 Troubleshoo...

Page 4: ...and all other instructions Keep the manual for future reference Make sure that it is available to all those using the device If you sell the unit please make sure that the buyer also receives this man...

Page 5: ...ord search Use the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms P...

Page 6: ...rackets and italics Examples VOLUME control Mono button The individual steps of an instruction are numbered consecutively The result of a step is indented and highlighted by an arrow Example 1 Switch...

Page 7: ...angerous situation that will result in death or serious injury if it is not avoided WARNING This combination of symbol and signal word indicates a pos sible dangerous situation that can result in deat...

Page 8: ...arning signs Type of danger Warning corrosive substances Warning high voltage Warning extreme cold Warning harmful or irritating substances Warning danger zone General information Ground Fog Machine 8...

Page 9: ...erating con ditions is considered to be improper and may result in personal injury or property damage No liability will be assumed for damages resulting from improper use This device may be used only...

Page 10: ...etach any small parts e g knobs or the like from the unit They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by high voltages ins...

Page 11: ...anger of frostbite when handling dry ice Dry ice is frozen carbon dioxide CO2 at a temperature of 87 5 C Direct contact of dry ice with the skin causes severe frostbite Never touch dry ice with bare h...

Page 12: ...consciousness nausea or vomiting Keep dry ice containers in a well ventilated area where children can not gain access WARNING Danger of slipping from condensed water Dripping condensation may cause th...

Page 13: ...ar any direct heat source Keep the device away from naked flames NOTICE Operating conditions This device has been designed for indoor use only To prevent damage never expose the device to any liquid o...

Page 14: ...evice before electrical storms occur and when it is unused for long periods of time to reduce the risk of electric shock or fire NOTICE Possible staining The plasticiser contained in the rubber feet o...

Page 15: ...tures This fog machine is suitable for use in clubs bars discotheques and on stages Special features of the device n High efficiency heating element n Large water tank n Robust housing Features GF 300...

Page 16: ...ckaging To fully protect the device against vibration dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage res...

Page 17: ...5 Connections and operating elements Connections and operating elements GF 3000 17...

Page 18: ...he required operating temperature 4 HEATING Red indicator light Lights when the unit is heating up 5 Mains cable for power supply 6 Connecting cable to the heating element 7 Fog nozzle 8 Heating eleme...

Page 19: ...ouch dry ice with bare hands When handling dry ice wear suitable pro tective gloves and ensure appropriate eye protection If you break up large blocks of dry ice cover them first with a towel or a clo...

Page 20: ...tank wipe the edge clean with a cloth 6 Fold down the lid and close the lid fastening 7 Wait until the green indicator light 3 comes on Now the water has reached the required temperature for fog gener...

Page 21: ...nk to avoid no load running Disconnect the device from the mains Transport the device only when it is completely cooled down To avoid leaking water during transport you should transport the device onl...

Page 22: ...ter container capacity 8 2 l Dry ice bin capacity 2 2 kg Warm up time approx 15 min Operating supply voltage AC 230 V 50 Hz Power consumption 2530 W Dimensions W H D 415 mm 360 mm 350 mm Weight 7 55 k...

Page 23: ...Check the water level Fill in so much water that the water level sensor in the supply tank is completely under water No fog output 1 When the red indicator light is lit the unit is still heating up Wa...

Page 24: ...operating environment wet smoky or particularly dirty surroundings can cause more accumulation of dirt on the device parts n Clean with a soft dry cloth n Stubborn stains may be removed with a slight...

Page 25: ...r water In case of contact with eyes see a doctor If swallowed seek medical advice immediately and show the packaging or label The appliance should be descaled regularly This shortens the heating time...

Page 26: ...ins plug 7 Open the lid fastening 2 and open the lid Fill one portion of the descaling agent dosage according to manufacturer s instructions into the supply tank 8 Fold down the lid and close the lid...

Page 27: ...ng Please follow the notes and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE Do not dispose with your normal household wast...

Page 28: ...Notes Ground Fog Machine 28...

Page 29: ...Notes GF 3000 29...

Page 30: ...Notes Ground Fog Machine 30...

Page 31: ......

Page 32: ...Musikhaus Thomann Treppendorf 30 96138 Burgebrach Germany www thomann de...

Reviews: