4
Finishing Brands UK Limited,
Ringwood Road,
Bournemouth,
BH11 9LH,
UK.
Tel.No: 01202 571111
Fax No: 01202 581940
Website address: http:// www.finishingbrands.eu
CLEANING
1. For routine cleaning, it is not necessary to remove
cup from gun. Remove lid and properly dispose
of any excess paint. Pour in a small amount of
clean solvent. The amount will vary with different
coatings and solvents. Reinstall lid. Shake cup to
wash down the inside surfaces. Pull trigger to
allow some solvent to be flushed through gun.
Remove lid and pour out dirty solvent. Add a
small amount of clean solvent and repeat
procedure. Wipe exterior of lid with a clean cloth
and clean solvent.
2. If a paint filter was used in the bottom of the cup
outlet, it should be removed and cleaned at this
time.
3. To clean air cap and fluid tip, brush exterior with a
stiff bristle brush. If necessary to clean cap holes,
use a broom straw or toothpick if possible. If a
wire or hard instrument is used, extreme care
must be used to prevent scratching or burring of
the holes which will cause a distorted spray
pattern.
4. To clean fluid passages, remove excess material
at source, then flush with a suitable solvent. Wipe
gun exterior with a solvent dampened cloth.
Never completely immerse in solvent as this is
detrimental to the lubricants and packings.
PREVENTATIVE MAINTENANCE
Spray Gun Lubrication
1. Apply a drop of SSL-10 spray gun lube at trigger
bearing stud and the stem of the air valve. The
shank of the fluid needle where it enters the
packing nut should also be oiled. The fluid needle
packing should be kept soft and pliable by
periodic lubrication.
2. Make sure the baffle and retaining ring threads are
clean and free of foreign matter. Before assembling
retaining ring to baffle, clean the threads
thoroughly, then add two drops of SSL-10 spray
gun lube to threads.
3. The fluid needle spring and air valve spring should
be coated with a very light grease, making sure that
any excess grease will not clog the air passages.
For best results, lubricate the points indicated,
daily.
A. Trigger Points
B. Packing
C. Adjusting Valves
D. Baffle/Air Cap Threads
E. Needle adjusting knob and spring (inside knob).