background image

Instruction Manual

13

Note: To use the OAM functions, the 

802.3ah Functions

 setting must be Enabled 

(Default: Disabled). 

802.3ah Mode –

 (Default: Passive) Used to configure an OAM pair. In a pair, one unit 

must be ‘active’, while the other must be ‘passive’. Typically the remote converter (CPE) 

would be in ‘passive’ mode and the local in ‘active’. 

Link Events –

 Enable / Disable reporting of Link Events via OAM.

Remote Loopback –

 (Default: Disabled) In order to do a Remote Loop Back test, the 

option must be enabled in both converters. 

Unidirection Support – 

Enable / Disable reporting if Unidirectional Link Detection 

events via OAM.

Errfrm_Win (Error Frame Window) – 

(Default: 2 seconds) Adjustable from 1 to 60 

seconds. This is the "Window" of time used to gather error frames.

Errfrm_Thr (Error Frame Threshold) -

 This threshold count can be set from 1 up to 2 x 

1032. This count in conjunction with the error frame window, will determine if the Error 

Frame event is reported via OAM.

Errfrmprd_Win (Error Frame Period Window) –

 (Default: 148800) This frame count 

window can be set from 1 up to 2 x 1032 to gather the number of frame errors within 

the last x frames.

Errfrmprd_Thr (Error Frame Period Threshold) -

 This threshold count can be set 

from 1 up to 2 x 1032. This count in conjunction with the frame window will determine 

if the Error Frame Period event is reported via OAM.

Summary of Contents for 8STET91000LCOAM

Page 1: ...tech com FR Guide de l utilisateur fr startech com ES Gu a del usuario es startech com IT Guida per l uso it startech com NL Gebruiksaanwijzing nl startech com PT Guia do usu rio pt startech com ET910...

Page 2: ...eceiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer...

Page 3: ...on 2 Packaging Contents 2 System Requirements 2 Factory Reset Procedure 2 Installation 3 Installation into ETCHS2U Chassis 4 Operation 4 System Information Section 5 Local Settings Section 6 Tools Sec...

Page 4: ...en indicates Fast Ethernet 100Mbps while Yellow indicates Gigabit Ethernet When the LEDs are off it indicates a speed of 10Mbps Default Use to recover from lost password or to return all settings to f...

Page 5: ...5e or better Ethernet cable Available AC electrical outlet Factory Reset Procedure Apply power to the unit and allow approximately 30 seconds to fully boot Using a pencil or a ball point pen press the...

Page 6: ...a computer switch to the RJ45 jack on the media converter 3 Connect the power adapter to the media converter The following example illustrates the connection scheme when connecting from a 1000BASE T...

Page 7: ...ously unused loosen the screw at the top of the slot to remove the cover plate 2 Align the card with the desired slot of the chassis and gently slide the card into the groove to seat the power connect...

Page 8: ...configuration options and tool which will be explained in the following pages System Information Section Network Information The information displayed on this page gives specific device information n...

Page 9: ...be displayed via the web user interface Local Settings Section IP Configuration Use this screen to configure TCP IP settings for the local unit Click the Apply button to save your settings Note Chang...

Page 10: ...Key in the current password Default admin and then enter your desired new password twice Click the Apply button to save your settings Converter Configuration The Converter configuration menu includes...

Page 11: ...ames defined in IEEE802 3x normally used by the switch to throttle packets through a bottleneck rather than drop excess packets E g A 1Gbps stream is exiting a 100Mbps port Normally pause frames are n...

Page 12: ...ling the port setting auto or forced Ethernet mode enabling 802 3x flow control and setting ingress and egress rate limiting Note Rate limiting has a granularity of 64K so the rate can be set from 64k...

Page 13: ...t the access to different VIDs can be controlled Click the Apply button to save your settings Per Port Configuration ET91000LCOAM actually has three different ports the external copper external fiber...

Page 14: ...they are tagged The switch will not modify packets received without tags 3 Add Tag The switch will add VLAN tags to packets if they are not tagged when these packets are output on this port The switc...

Page 15: ...configure a management VLAN and designate which ports it can be accessed from Click the Apply button to save your settings 802 3ah Functions Section This converter supports IEEE 802 3ah an OAM protoco...

Page 16: ...tional Link Detection events via OAM Errfrm_Win Error Frame Window Default 2 seconds Adjustable from 1 to 60 seconds This is the Window of time used to gather error frames Errfrm_Thr Error Frame Thres...

Page 17: ...OAM frames used the number of times the loop back is done Packet Length Not including CRC Default 60 bytes Controls the packet size of the OAM frames used for loop back testing The CRC of Ethernet pac...

Page 18: ...leared and the converter starts fresh If OAM is enabled the discovery process will start After selecting the System Reboot menu item a confirmation dialogue box will pop up Click OK to reboot the conv...

Page 19: ...oadFromFlash button To restore all settings to factory default click the ResetToFactory button Note The IP address will also be reset to default 10 1 1 1 so you may lose management contact with the co...

Page 20: ...Instruction Manual 17 Logging Out Click the Logout button at the bottom of the web interface to terminate your session Once logged out the username password will be required to login again...

Page 21: ...returned for repair or replacement with equivalent products at our discretion The warranty covers parts and labor costs only StarTech com does not warrant its products from defects or damages arising...

Page 22: ...Instruction Manual 19...

Page 23: ...ts and we quickly deliver them wherever they need to go Just talk to one of our tech advisors or visit our website You ll be connected to the products you need in no time Visit www startech com for co...

Reviews: