DATA OUTPUT CONNECTION

To connect an output cable, remove the two small Phillips screws as shown 
below. Then, remove the output port cover. 

Plug in the cable and secure it with the same screws that held the cover. 
Orient the data cable plug as shown below. When not using output, replace 
the data cover to protect the electronics

BATTERY REPLACEMENT

Remove the two Phillips screws that secure the battery drawer 

as shown below. 

Remove the battery drawer and discard the old batteries. 

Place two new CR2032 batteries into the tray with the positive (+) side facing up. Slide 

the tray carefully into the indicator and secure with the two screws.

To order CR2032 batteries, specify: PT99492. EDP 65650

Summary of Contents for FORM 966

Page 1: ...Trust Is In The Name User Manual FORM 966 ...

Page 2: ...TO LEA ATENTAMENTE ESTE MANUAL LIRE CE MANUEL AVANT D UTILISER L INSTRUMENT LEIA ATENTAMENTE ESTE MANUAL ANTES DE UTILIZAR O INSTRUMENTO 使用仪器前请阅读本操作手册 DIESES HANDBUCH VOR DER VERWENDUNG DES MESSGERÄTS LESEN LEGGERE ATTENTAMENTE QUESTO MANUALE PRIMA DI UTILIZZARE QUESTO STRUMENTO 01 18 Q ...

Page 3: ...2900 ELECTRONIC INDICATOR USER MANUAL ...

Page 4: ...eature Level and Resolution 9 Resolution Selection 9 Setting the Preset Function 10 Setting MIN MAX Limits Go No Go 10 Displaying MIN MAX TIR Values 12 Lock Mode 12 Data Output Connection 13 Battery Installation 13 Appendix A Technical Specifications 14 Appendix B Serial Output Connector 14 Available with Standard and Advanced Features Available only with Advanced Features ...

Page 5: ...RONIC INDICATOR THIS IS A STARRETT USER GUIDE FOR THE 2900 ELECTRONIC INDICATOR ALL SPECIFICATIONS IN THIS DOCUMENT ARE CORRECT AT TIME OF PRODUCTION AND ARE SUBJECT TO CHANGE PLEASE CONTACT STARRETT FOR FURTHER INFORMATION ...

Page 6: ...Do not apply lubricant to the spindle or use solvents 9 Do not disassemble or modify the indicator OPERATING INSTRUCTIONS 1 Install batteries included with indicator 2 Lightly clean the contact point 3 Secure the indicator to an appropriate holding device 4 Press the ON OFF button to turn the indicator on 5 Select the unit of measure inch or millimeter by pressing the IN mm button Not applicable t...

Page 7: ...ENGLISH Stem Cap Data Cable Spindle Bellows Spindle Contact Point Stem Data Output Cover Battery Drawer Back Lug 1 21 32 42 2mm 1 4 6 5mm 1 4 6 5mm 2 5 64 53mm 3 8 9 5mm INDICATOR COMPONENTS DIMENSIONS AND LAYOUT ...

Page 8: ...the display 6 LOCK Prevents operator modification to the Settings Press SHIFT SET button then press and hold the LOCK button after setting the other functions 7 RES Resolution First select the Unit English Metric Press SHIFT SET then the RES Plus Minus buttons Press the RES button to scroll through choices and press the SHIFT SET to make the selection 8 LIMITS Sets the Min and Max values for the G...

Page 9: ...0 2 09981 Basic English Metric 0001 001mm 5 12mm 2900 4 09983 Standard English Metric with Selectable Resolution 0005 0001 00005 01mm 001mm 5 12mm 2900 6 09985 Advanced English Metric with Selectable Resolution 0005 0001 00005 01mm 001mm 5 12mm 2900 1M 09986 Basic Metric 001mm 12mm 2900 4M 09988 Standard Metric with Selectable Resolution 01mm 001mm 12mm 2900 6M 09990 Advanced Metric with Selectabl...

Page 10: ...T button and repeat step 3 Repeat steps 2 and 3 until all the digits are SET 5 Tosetanegativevalue pressPRESETwhentheplus minussigniconisflashing 6 To exit the PRESET function press the PRESET button when the PRESET icon is flashing The SET value will remain displayed 7 Press and hold the ZERO ABS button to return to the active measuring mode SETTINGMIN MAXLIMITS GO NOGOFUNCTION 1 Select the units...

Page 11: ...eyond the set limits the display will flash and the MIN or MAX LIMIT icon will indicate the direction the limit have been exceeded To exit Press the LIMITS button Press SHIFT SET BUTTON Then LIMITS Button to enter Min Limit Mode Press SHIFT SET BUTTON The LIMIT icon will flash on off Press SHIFT SET BUTTON to increment the value of the digit or the plus minus sign Then press SHIFT SET BUTTON To ca...

Page 12: ... MIN MAX TIR settings These values are stored in memory Then lock these settings as follows 1 Press the SHIFT SET then press and hold the LOCK button 2 The Lock icon will turn on and stay on see right Once the lock mode has been activated the operator will not be able to change ABS Normal Mode Limits Units PRESET or MAX MIN TIR but will have access to the zero function and be able to view MIN MAX ...

Page 13: ...e plug as shown below When not using output replace the data cover to protect the electronics BATTERY REPLACEMENT Remove the two Phillips screws that secure the battery drawer as shown below Remove the battery drawer and discard the old batteries Place two new CR2032 batteries into the tray with the positive side facing up Slide the tray carefully into the indicator and secure with the two screws ...

Page 14: ... displacement stored MX Displacement is minimum peak displacement stored TR Displacement is the T I R stored LL Displacement is the lower or minimum limit setting LU Displacement is the upper or maximum limit setting HL Displacement is a held displacement 1 Sign character minus but no plus 1 Space character IN mode only 6 Digits 1 Decimal point 2 Spaces 1 Character strings to indicate units IN or ...

Page 15: ...l Order Only State Change High to Low SERIAL INPUT VOLTAGE LEVEL SPECIFICATION Logic 0 Vin 1 30 Volts Logic 1 Vin 1 98 Volts SERIAL OUTPUT VOLTAGE LEVEL SPECIFICATION MINIMUM MAXIMUM Low Level Vss Vss 0 25 1 5mA Load High Level Vdd 0 25 1 25 mA Load Vdd Note Vss 0 Volts Vdd 2 7 to 3 6 Volts ENVIRONMENTAL CONSIDERATION Temperature 10 30 C Humidity 30 85 RH no condensation Atmosphere Non corrosive N...

Page 16: ...Starrett com ...

Reviews: