ENGLISH AND METRIC

 

 ELECTRONIC DIGITAL MICROMETER SERIES

 

This manual covers the following electronic series:  

714.1 Interchangeable Anvils, 733.1 XFLZ, MEXFLZ and 

MXRL Micrometer, 749.1 Depth Gage, 756.1Disc Mic, 760.1 

Screw Thread Mic, 762.1 Mic Head, 764.1 Sheet Metal Mic, 

769.1 Tube Mic, 777.1 Bench Mic, 786.1 Blade Mic, 788.1 

Rounded Anvil Mic, 790.1 Multi- Anvil Mic 

USER MANUAL

 

733.1XFL-1 ELECTRONIC MICROMETER 1"

 

Summary of Contents for 714.1

Page 1: ...eries 714 1 Interchangeable Anvils 733 1 XFLZ MEXFLZ and MXRL Micrometer 749 1 Depth Gage 756 1Disc Mic 760 1 Screw Thread Mic 762 1 Mic Head 764 1 Sheet Metal Mic 769 1 Tube Mic 777 1 Bench Mic 786 1 Blade Mic 788 1 Rounded Anvil Mic 790 1 Multi Anvil Mic USER MANUAL 733 1XFL 1 ELECTRONIC MICROMETER 1 ...

Page 2: ...o the spindle and do not use solvents Avoid using anything that might damage the buttons when pressing the buttons It is important to wipe the micrometer with a lint free cloth after exposure to moisture Do not use aggressive solvents to clean the plastic components Do not store the instrument in areas of extreme temperature The spindle is designed not to be removed from the tool and should not be...

Page 3: ...l a number from 0 9 in every position After all the numbers are installed Press the SET button again and the display will flash between Shift and Preset Press the PRESET button to install the new preset number and the Shift and Preset will stop flashing Finally double check to see that the numbers are correct and the spindle is in the proper position IN mm LIMITS Button The micrometer can be chang...

Page 4: ...onds until the display changes to show measurement readings This movement will initialize the accuracy tuning function and calibrate the indicator This feature will happen each time the batteries are changed If you don t move the spindle CAL will stay on the display If you move the spindle to fast it will take longer for the tool to initialize 5 0 Zero Sequence After CAL mode is completed press th...

Page 5: ...ero Abs button the spindle must not be moved until the Zero Sequence has elapsed See New Zero Sequence on page 5 Press and hold for 2 seconds to activate the ABS mode Press and hold again for 2 seconds more to exit the ABS mode Press the Shift Set button shift will be displayed and then press the Preset Zero Abs button to get to Preset Mode 3 SHIFT SET Press this button to access Limits and Preset...

Page 6: ...end the range of the system when needed There are three 795 1 Smart cables that allow you to connect to a computer via a USB port 795 1SCU connects through a USB port on your computer and is used with data collection software 795 1SCKB connects to a USB port on your computer but is plug play like a Key Board You can send data to a number of windows programs like a spreadsheets databases programs 7...

Page 7: ...attery cover making sure the rubber gasket is positioned correctly on the cover and secure The display will flash until the DATUM button is depressed See New battery Startup Sequence on page X for further instructions NOTE When the battery is getting weak the display will get dim and show a battery icon in the bottom left side as seen below Fig 7A Make sure you replace the batteries with two type ...

Page 8: ...t Battery Life Greater than one year with normal use Serial Data 4800 BAUD 8 bits No Parity 1 stop bit ASCII data Transmission is exactly 16 characters followed by a carriage return and a line feed Dust Water Protection IP67 according to IEC60529 0 4 and 0 100mm ONLY 6 The first number identifies protection against complete ingress of dust 7 The second number identifies protection against the effe...