12 Specifications
Type: ISC CLDC
Unit
Value
Voltage
V
36
Rated power
W
850
Max. Output power
W
900
Air flow*
l/s (m³/h)
66 (238)
Vacuum*
hPa/MG
240
Air flow**
l/s (m³/h)
38 (137)
Vacuum**
hPa/SE
213
Sound level L
pA
/ L
WA
dB(A)
72 / 86 ±2
Weight
kg
12.6
Dimensions L x W x H
cm
46 x 40 x 57
Container volumes
l
25
Vibration measurement
m/s
2
0.08 ±0.01
* at the cooling fan
**at the hose
13 Tests and approvals
Electrotechnical tests are to be carried out in accordance with the regulations for the prevention of accidents (DGUV V3) and DIN VDE 0701
Part 1 and Part 3. These tests are required at regular intervals and after repair or modification in accordance with DIN VDE 0702.
The vacuum cleaners have been successfully tested according to IEC/EN 60335–2–69.