Switching on
Set the two manual valves (2.1 / 2.2) to RELEASE.
Switch on the device with the switch (3). The pumps must start up if the vacuum is insuffi-
cient. The pump indicator light (4.1 / 4.2) indicates that the pumps are active. If this is not
the case, working with the KS Vacu Power is not permitted (see Troubleshooting) the sig-
nal tone indicates insufficient vacuum.
After a short period, a vacuum of at least -0.65 bar should have built up. The vacuum
pumps switch off when approx.
–0.7 bar is reached. This should be the case after a short
time.
As long as no transported goods are sucked on or the suction pads, it is not possible to
check the vacuum from the two inspection vacuum meters (5.1 / 5.2).