background image

GENERAL SAFETY WARNINGS

Read all safety warnings and instructions. Failure to follow the warnings and instructions may 

result in electric shock, fire and/or serious injury. Save all warnings and instructions for future 

reference. 

SAFETY 

The warnings, precautions, and instructions discussed in this instruction manual cannot cover all 

possible conditions and situations that may occur. It must be understood by the operator that common 

sense and caution are factors which cannot be built into this product, but must be supplied by the 

operator. Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before 

operating. Failure to follow the safety rules and other basic safety precautions may result in serious 

personal injury.

1

Read and understand all instructions.

 Failure to follow all instructions may result in serious injury

or property damage.

DO NOT

 allow persons to operate or assemble the product until they have read this manual and have 

developed a thorough understanding of how it works.

DO NOT modify this product in any way. 

Unauthorized modification may impair the function and/or

safety and could affect the life of the product. There are specific applications for which the product

was designed. 

Use the right Pump for the job. DO NOT

 attempt to force a small Pump or attachment to do the work 

of a larger industrial Pump. There are certain applications for which this Pump was designed. 

DO NOT

 

modify this Pump and do not use this Pump for a purpose for which it was not intended.

Maintain Pump with care.

 Inspect tool cords periodically and, if damaged, have them repaired by an 

authorized technician. 

I

nspect  the  work  area  before  each  use

. Keep work area clean, dry, free of clutter, and well-lit. 

Cluttered, wet, or dark work areas can result in injury. 

Do not use the product where there is a risk of causing a fire or an explosion

; e.g., in the presence 

of flammable liquids, gases, or dust. The product can create sparks, which may ignite the flammable 

liquids, gases, or dust.

Guard against electric shock.

 Prevent body contact with grounded surfaces such as pipes, radiators, 

ranges, and refrigerator enclosures. It is strongly recommended that this Pump be plugged into a 

Ground Fault Circuit Interrupter (GFCI). Ask a local electrician for easy installation instructions. To 

avoid electrical shock, no person or animal should be in contact with the water being pumped. Never 

walk on wet or damp area when pump is running in the same room.

Keep children and bystanders away from the work area while operating the pump.

 

DO NOT

 

allow children to handle the product. 

IMPORTANT SAFETY INFORMATION

Summary of Contents for 71042

Page 1: ...G INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 71042 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 4900 MON FRI 9AM TO 3PM PST ...

Page 2: ...he product was designed Use the right Pump for the job DO NOT attempt to force a small Pump or attachment to do the work of a larger industrial Pump There are certain applications for which this Pump was designed DO NOT modify this Pump and do not use this Pump for a purpose for which it was not intended Maintain Pump with care Inspect tool cords periodically and if damaged have them repaired by a...

Page 3: ...cause electrical damage to the tool This tool requires use of an extension cord of 0 to 10 amps capability up to 50 feet with wire size rated at 18 AWG Longer extension cords require larger size wire If you are using the tool outdoors use an extension cord rated for outdoor use signified by WA on the jacket Note DO NOT make the extension cord connection underwater Maintenance For your safety maint...

Page 4: ...SAL FITTING Powered by a durable oil cooled electric motor Various fittings for outflow included Heavy Duty Motor with thermal overload protection About 25 Ft Cord Length Foldable pump base for max drain FEATURES SPECIFICATIONS PART LIST PRODUCT INFORMATION ...

Page 5: ...utlet fitted with a Ground Fault Circuit Interrupter GFCI 2 The pump will automatically turn on when the water level has filled to approximately 3 above the base It will stop when the water level drops below 3 It will continue to recycle thereafter 3 Check that the discharge water travels several feet from the foundation FLOAT SWITCH ADJUSTMENT There is a Float Switch Lock that is part of the Rear...

Page 6: ...ing inlet cleaning disconnect the pump from the outlet 3 Periodically clean the Lower Base remove the Screws from the Base and remove any dirt or debris Replace the Lower Base NOTE Many problems occur due a clogged Lower Base Remove the Screws from the Lower Base and remove the Lower Base Clean out dirt or debris from the bottom of the Pump and replace Lower Base using the same screws TROUBLESHOOT...

Page 7: ...HAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial number record mon...

Reviews: