82
Section 6: Electrical System
Load Center
The Load Center contains 12VDC fuses
and 120VAC circuit breakers for almost
all of the electrical appliances and cir-
cuits in the RV. The 120V main breaker
may be located in this panel and will turn
off all 120-volt power to the RV. Loca
-
tions will vary by model. Refer to the
diagram inside the load center for spe-
cific fuse assignments.
Motorhomes may have separate small
panels for breakers and fuses. They are
normally located in close proximity to
each other typically in the bed platform. The converter is also mounted separately (typically
under the bed platform).
120-Volt Circuit Breakers
The 120-volt AC circuit breakers located inside the load center protect all 120-volt wiring
and components from circuit overloads and short circuits. Should a circuit overload or short
circuit occur the circuit breaker protecting the affected circuit will “trip” preventing the flow
of electricity through that circuit.
If a circuit breaker trips, shut off the appliance on that circuit (i.e., power converter, etc.)
and allow the circuit breaker to cool down for a brief period of time. After it cools down,
reset the circuit breaker by moving its lever “off” and then back to the “on” position. If the
circuit breaker re-trips or frequently trips, contact your dealer to have the electrical problem
diagnosed and repaired.
A circuit breaker identification label is permanently attached to the inside surface of the 120-
volt Load Center.
Replacement
Only replace circuit breakers with those of the same specified type, voltage, and current rat
-
ing.
Never replace a circuit breaker with one listed at a higher amperage rating.
Please
contact your dealer for repair assistance when replacing circuit breakers.
Maintenance
At the beginning of the camping season, inspect the circuit breakers and replace as needed.
Test by turning each circuit breaker “off” and back “on”. Circuit breakers are wearable parts
Circuit breakers and fuses will not offer complete protection of the electrical
system in the event of power surge or voltage spike.
Replacement circuit breakers must be of the same voltage, amperage rating
and type. Never use a higher rated replacement circuit breaker; doing so may
cause a fire by overheating the RV wiring.
Table of Contents
Maintenance Record
Summary of Contents for SUPER LITE 2021
Page 1: ...2021 Owner s Manual 0335747 2021 Asubsidiary of Thor Industries Inc Travel Trailers...
Page 2: ......
Page 32: ...30 Section 2 Occupant Safety Table of Contents Maintenance Record...
Page 42: ...40 Section 3 Pre Travel Information Notes Table of Contents Maintenance Record...
Page 90: ...88 Section 6 Electrical System Notes Table of Contents Maintenance Record...
Page 100: ...98 Section 7 Fuel Propane System Notes Table of Contents Maintenance Record...
Page 126: ...124 Section 8 Plumbing System Notes Table of Contents Maintenance Record...
Page 138: ...136 Section 10 Appliances Notes Table of Contents Maintenance Record...
Page 140: ...138 Section 11 Electronics Notes Table of Contents Maintenance Record...
Page 153: ...151 Section 13 Exterior Travel Trailers Sealant Diagram Maintenance Record Table of Contents...
Page 154: ...152 Section 13 Exterior Notes Table of Contents Maintenance Record...