Section 8: Plumbing System
Water Heater Bypass
Use the factory installed water heater bypass, available in most floor plans, to avoid filling
the entire water heater with RV antifreeze. See the
Utility Center
section for details on using
the bypass system.
High Altitude Deration
Operation of the water heater at high altitudes may require derating. If the water heater is not
properly derated, lack of sufficient oxygen for combustion may produce improper burner
operation. Pilot outage caused by burner lift-off or sooting from a yellow burner may occur,
indicating the possibility of carbon monoxide. You may also notice a lack of efficiency in
heating the water because of incomplete combustion of the burner at these higher altitudes.
Consult with the local propane company, your dealer or the water heater manufacturer for
proper derating of the water heater. Change out of the orifice (derating) should be done by
the dealer or a qualified service agency.
Pressure and Temperature Relief Valve
The temperature and pressure relief valve is designed to open if the temperature of the water
within the heater reaches 120° F, or if the water pressure in the heater reaches 150 pounds.
When this pressure is reached, the pressure relief valve will open and water will drip from
the valve.
This “weeping” or dripping will continue until the pressure is reduced to below 150 pounds,
and the valve closes. This condition is normal and does not indicate a defective relief valve.
One way to reduce the frequency of this occurrence is to maintain an air pocket at the top
of the water heater tank. This air pocket will form in the tank by design; however, it will be
reduced over time by the everyday use of your water heater.
To replenish this air pocket:
1.
Turn off the water heater.
2.
Turn off the cold water supply line.
3.
Open a faucet in the recreation vehicle.
4.
Pull out the handle of the pressure relief (P&T) valve and allow water to flow from the
valve until it stops.
5.
Release the handle on the P&T valve - it should snap closed.
Close the faucet and turn on the cold water supply. As the tank fills, the air pocket will
develop. Repeat this procedure as often as needed to reduce the frequency of the weeping
P&T valve.
NOTE:
It is important that once the RV has returned to lower
elevation (below 4500 feet) any high altitude deration or other adjust
-
ments be reversed for proper operation of the water heater.
Do not place a valve between the pressure and temperature (P&T) valve and
the tank. Do not remove or plug the relief valve under any circumstances.
Table of Contents
Maintenance Record
Summary of Contents for SUPER LITE 2021
Page 1: ...2021 Owner s Manual 0335747 2021 Asubsidiary of Thor Industries Inc Travel Trailers...
Page 2: ......
Page 32: ...30 Section 2 Occupant Safety Table of Contents Maintenance Record...
Page 42: ...40 Section 3 Pre Travel Information Notes Table of Contents Maintenance Record...
Page 90: ...88 Section 6 Electrical System Notes Table of Contents Maintenance Record...
Page 100: ...98 Section 7 Fuel Propane System Notes Table of Contents Maintenance Record...
Page 126: ...124 Section 8 Plumbing System Notes Table of Contents Maintenance Record...
Page 138: ...136 Section 10 Appliances Notes Table of Contents Maintenance Record...
Page 140: ...138 Section 11 Electronics Notes Table of Contents Maintenance Record...
Page 153: ...151 Section 13 Exterior Travel Trailers Sealant Diagram Maintenance Record Table of Contents...
Page 154: ...152 Section 13 Exterior Notes Table of Contents Maintenance Record...
Page 158: ...156 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record...