background image

 

24 

 Information and settings 

S.Box Duo S and S.Box Duo ST 

Technical information concerning the device: 

 

 

 

Views of the display

:

 

 

❽ 

Tap the touch key 

 

 
 

 

 

 

 
Accessing 

the 

technical 

information 

concerning the device. 
 

Tap the key 

 to display the information. 

❾ 

Tap the touch key 

 

 
 

 

 

 

 
Identification number of six digits specific to 
the  patient  is  automatically  assigned  by  the 
device. 

❿ 

Tap the touch key 

 

 
 

 

 

 

 
Software version 
 
This is the version of the embedded software 
of the device. It can be read but not modified. 

⓫ 

Tap the touch key 

 

 
 

 

 

 

 
Total usage hour counter 

 

This counter calculates the total time during 
which  you  have  been  breathing  into  the 
mask. 
 

⓬ 

Tap the touch key 

 

 
 

 

 

 
Total machine hour counter 
 
This  counter  calculates  the  total  operating 
time of the device. 

Summary of Contents for Sefam S.Box Duo S

Page 1: ...S Box Duo S S Box Duo ST...

Page 2: ...r S Box Duo S or your S Box Duo ST Easily monitor the evolution of the effectiveness of your treatment and other parameters of your health and well being Share this data with your healthcare professio...

Page 3: ...ures 12 Using an SD card 13 Transporting the device 14 Information and settings 15 User interface description 15 How to set the device 17 Using the device with oxygen enrichment optional 28 Installati...

Page 4: ...ected to a multi socket outlet do not connect the system to any other multi socket outlet or extension cable Be careful not to accidentally or intentionally block the air outlet or any opening of the...

Page 5: ...ning of the upper airways The performance of the device may alter if a heated humidifier is installed There is a risk of air leak when the humidifier chamber or side cover is not attached properly whi...

Page 6: ...ehydratation Tracheotomy Adverse effects If any of the following symptoms appear while using the device which may in certain cases require temporary cessation of treatment please contact your healthca...

Page 7: ...midifier chamber or side cover intended for unlocking the side cover or the humidifier chamber and removing it from the machine It also identifies the model of the device or 5 SD card slot Slot for in...

Page 8: ...is symbol indicates the maximum water level which should not be exceeded in the chamber On the humidifier chamber this symbol indicates that it is necessary to open the chamber and remove its cover be...

Page 9: ...Box modem S Box Wi Fi module or PolyLink system into the accessory slot mark 10 in Figure 4 we herefor refer to the corresponding instructions in the installation and usage procedure 3 Then place the...

Page 10: ...h key or any button the hibernation mode screen appears The touch key home permits to return the screen from hibernation to standby screen to turn off the display from the standby screen Standby scree...

Page 11: ...rk Fill the chamber only with water at room temperature do not use hot or chilled water It is recommended to use distilled water Do not add any product to the water in the chamber essential oils etc D...

Page 12: ...by tapping the touch button Adjust your mask in case of undesired leak Tap to return to the standby screen Mask unplugged If you remove your mask the device automatically reduces the flow The machine...

Page 13: ...peration can be performed only once Backing up the data If the data is recorded within the device the data backup starts automatically when you insert the memory card into the machine turn on the powe...

Page 14: ...the opening clip upwards to release the upper part of the chamber then put it aside Empty the water Then unlock the heater plate by pushing the latch to the right and remove it Pack it with the humidi...

Page 15: ...tion When the device is in operation information appears on the touch screen in front and you may be able to adjust certain settings The available parameters are settings for your treatment general se...

Page 16: ...rogress Settings values units and symbols displayed Numbers or letters Pressure unit hecto Pascal or cm H2O Flow unit liter per minute Time unit hour and minute Caution the device detected an error or...

Page 17: ...ly possible if your device is equipped with a S Box heated tube with ATC Tap to return to the standby or operation screen 2 Humidification level if humidifier installed Tap the touch key in standby or...

Page 18: ...bled by your Home Care Provider By tapping the key or as many times as necessary you can decrease or increase the value displayed or disable the ramp feature in selecting Possible settings OFF and fro...

Page 19: ...device via a Bluetooth connection to make adjustments via tablet smartphone applications refer to the corresponding instructions for use If your device is equipped with a communicating accessory S Bo...

Page 20: ...rmanent Then you go back to the WPS screen and you can resume the settings menu C BLE communication BLE Bluetooth Low Energy or Tap the touch key You can disable OFF or enable ON the communication by...

Page 21: ...e The device searches for the BLE module and the display blinks alternately with six dashes as long as no module is associated Once detected the last six digits of the Bluetooth address of the PolyLin...

Page 22: ...allows leaving the menu Information concerning a period of use A period of 24 hour use is set from noon to the next noon Views of the display Tap the touch key in standby mode Accessing a period of us...

Page 23: ...iance value time during which you have been breathing in the mask during the period of use Tap the touch key Average breath rate delivered during the period of use Tap the touch key Number of the last...

Page 24: ...fication number of six digits specific to the patient is automatically assigned by the device Tap the touch key Software version This is the version of the embedded software of the device It can be re...

Page 25: ...e previous display leaves the current menu Tap the touch button when the device is in operation SD card status Possible displays SD OK and SD _ _ _ If SD _ _ _ is displayed check that the SD card is p...

Page 26: ...position sensor Possible displays POS lying on back POS lying on stomach POS lying on right side POS lying on left side POS standing POS sensor inverted If POS is displayed check that the PolyLink sy...

Page 27: ...of the machine at the first pairing View of the display Tap the touch key Enable pairing or Refuse to pair The display disappears after 30 seconds 9 Airplane mode In an airplane or in public places su...

Page 28: ...ygen must not exceed 8 l min CAUTION At a fixed oxygen flow the concentration of inhaled oxygen varies depending on the settings of pressure your breathing pattern type of mask and leakage rate This a...

Page 29: ...e install the humidifier chamber once it is dry o Fill the bottom part of the humidifier chamber then press down on the upper part to close the chamber and lock it o Place the humidifier chamber back...

Page 30: ...ce a month or more if it is visibly dirty Change filters as soon as they are torn or stained It is recommended to change the washable filter every 6 months Humidifier if installed Once the humidifier...

Page 31: ...eaction to mask components Adjust the headgear Contact your doctor or Home Care Provider to try different sizes Stop using the mask Contact your doctor or the Home Care Provider Dryness or irritated e...

Page 32: ...humidifier does not appear to heat the water The humidification level is set on OFF Set the humidification level between 01 and 10 see section How to set the device page 16 Water droplets appear in th...

Page 33: ...l power sources Plug it in again and turn it on If the problem persists contact your Home Care Provider This symbol flashes on screen The device detected a malfunction of the heated tube Check the tub...

Page 34: ...ameter Expected life of the device 5 years for a typical use of 8 hours a day Air inlet filters Optional high efficiency filter Disposable fabric HEPA filter which is 90 effective for particles 3 micr...

Page 35: ...20 Maximum power consumption 75 W during a mask disconnection Current consumption at 20 cmH2O with a 4 mm leak 0 42 A minimum configuration S Box Duo S or S Box Duo ST only 1 99 A maximum configuratio...

Page 36: ...2021 Date of CE marking of S Box Duo ST 2021 Regulatory Requirements Risks concerning this medical device are evaluated according to the ISO 14971 2019 standard specifically with regard to global resi...

Page 37: ...t humidifiers for medical use Particular requirements for respiratory humidification systems ISO 80601 2 79 2018 Medical electrical equipment Part 2 79 Particular requirements for basic safety and ess...

Page 38: ...38 Technical characteristics S Box Duo S and S Box Duo ST...

Page 39: ......

Page 40: ...Manufacturing plant SEFAM 144 AV CHARLES DE GAULLE 92200 NEUILLY SUR SEINE FRANCE SEFAM 10 ALLEE PELLETIER DOISY 54600 VILLERS LES NANCY FRANCE M 164DFU03 80 Version 2 2021 08 Contact of your Home Ca...