GENERAL SAFETY INFORMATION
This equipment is designed and sold for commercial use only, and is intended for use by personnel
trained and experienced in its operation. This is not sold for consumer use in and around the home
nor for use directly by the general public in food service locations.
Before using your new equipment, read and understand all the instructions and labels associated
with the unit prior to putting it into operation. Make sure all people associated with its use understand
the units operation and safety before they use the unit.
GENERAL INSTALLATION INFORMATION
The unit is shipped fully assembled and ready to plug into a standard outlet specified for its voltage
and amp draw. If improper electrical supply can be determined through troubleshooting, contact
a qualified electrician prior to using the unit. Removal or replacement of the power cord or plug will
void the warranty. Should you require assistance, contact your local authorized service agent for any
service or required maintenance.
Level unit using the adjustable feet under the unit [there is approximately 0.5 (1/2) inch of adjustment].
Allow enough space around the unit for adequate ventilation. It is recommended that you leave a ten
(10)
inch gap on the top for cleaning if the unit is to remain stationary. The sides and back of the unit
require no additional clearance.
Before using the unit for the first time, make certain to clean it properly. Refer to the "Cleaning Procedure"
document for cleaning instructions. The inlet and outlet trays will also need to be placed on the unit prior to
use. The out
let
tray slides on the lip under and in front of the drum area and the inlet tray sits on a rod
,
resting against the stop pins.
ELECTRICAL CONNECTION
Before making any electrical connection to this unit, check that the power supply is adequate for the
voltage, amperage, and requirements stated on the rating plate. RTW14E
A
units will require a NEMA
5-
20P
receptacle. RTW
19
E
A
units will require a NEMA 6-
15
P
receptacle. Make certain to disconnect the
unit from the power source before installing or removing any parts. Be absolutely sure that the ground
connection for the receptacle is properly wired. Do not connect equipment to power without proper
ground connections. Improper grounding may result in personal injury or fatality.
DO NOT CUT OR REMOVE THE PLUG OR
DO NOT IMMERSE OR LET THE UNIT STAND
GROUNDING PRONG FROM THE PLUG.
IN WATER.
CONNECT UNIT INTO DEDICATED AC LINE
DO NOT HOSE DOWN THE UNIT OR THE
ONLY AS SPECIFIED ON THE DATA PLATE
TABLE/COUNTER IF THE UNIT IS ON THE
OF THE UNIT.
TABLE/COUNTER.
belt guide
belt roller
inlet tray
stop pin
place here
outlet tray