SHALLOW WELL JET PUMP

MODEL # ES05S, EK05S, CPH05S, ES07S, EK07S, ES10S, 

EK10S, JHU15S

IL1102

023448 J

110 West Division St. | Boonville, IN 47601

IL0068

Integral Jet 

Shallow Well Pump

Multi-purpose

Shallow Well Pump

For loose, missing or damaged parts, or if the 
unit does not seem to be operating properly, 
please call before returning unit to the place of 
purchase

Phone No.: 1-800-742-5044

Service Hours:

Monday thru Friday - 7:30 am to 5:00 pm EST

   

 

 

 

Summary of Contents for CPH05S

Page 1: ...oonville IN 47601 IL0068 Integral Jet Shallow Well Pump Multi purpose Shallow Well Pump For loose missing or damaged parts or if the unit does not seem to be operating properly please call before retu...

Page 2: ...Safety and Health Act OSHA 2 Replace damaged or worn wiring cord immediately 3 Do not kink power cable and never allow the cable to come in contact with oil grease hot surfaces or chemicals 4 Wire mo...

Page 3: ...he wire size is determined by the distance from the power source to the pump motor and the horsepower rating of the motor See the wire chart on page 11 for proper wire size GENERAL PUMP INFORMATION 1...

Page 4: ...AUTION Dry fit entire assembly to ensure proper fit before gluing or taping parts CAUTION Follow all proper gluing procedures as specified by the glue manufacturer Always glue in a vertical direction...

Page 5: ...MPT x 1 4 in FPT galvanized bushing and pressure gauge optional or a pipe plug Do not tighten as you will prime your pump later at this location Fig 3 2 Install a 3 4 x 3 4 x 3 4 in galvanized tee fi...

Page 6: ...NG The pump must be properly grounded using the proper wire cable with ground WARNING Always disconnect pump from electricity before performing any work on the motor IL1380 Pressure Switch 2 L1 L2 A B...

Page 7: ...ews on the strain relief Do not crush wire Fig 4 7 Insert an electrical wire strain relief into the opening in the opposite side of the pressure switch Fig 7 Wire from motor Pressure Switch Strain Rel...

Page 8: ...ddition to the pump cavity 1 Remove the priming plug with pressure gauge and air relief plug Fig 1a with built in ejector Fig 1b with bolt on ejector 2 IL1352 Water Level in Pump Cavity 3 3 Replace ai...

Page 9: ...e connections for leaks All connections must be water and air tight in order for pump to operate PUMP PRIMING STARTUP CONTINUED Breaker Box 6 6 Turn on breaker to start pump Fig 6 IMPORTANT If the pum...

Page 10: ...h water 1 Fill pump casing 2 Suction lift too high or too long 2 Move pump closer to water source 3 Hole or air leak in suction line 3 Repair or replace Use pipe tape and pipe sealing compound 4 Foot...

Page 11: ...ewired at the factory C If pump does not run check the GFI or breaker panel switch to make it is in full operation D If the pump runs all the time make sure the pump has been primed correctly If pump...