background image

12

13

PUMP ELECTRICAL CONNECTIONS (CONTINUED)

3.  Insert an electrical wire strain relief into the 

opening in the side of the pressure switch 

closest to the motor. (

Fig. 3

)

IL1372

3

IL1373

Wire from 

motor

4

IL1374

Wire from 

motor

5

IL1375

Wire from 

motor

Ground Screws

6

6.  Connect the green ground wire from the 

motor cable to one of the green ground 

screws at the bottom of the pressure switch. 

(

Fig. 6

)

5.  Connect the two motor wires of the motor 

cable to the two inside terminals on the 

pressure switch. (

Fig. 5

)

4.  Thread the cable from the pump motor 

through the strain relief into the pressure 

switch cavity and tighten both screws on the 

strain relief. Do not crush wire. (

Fig. 4

)

7.  Insert an electrical wire strain relief into the 

opening in the opposite side of the pressure 

switch. (

Fig. 7

)

Wire from 

motor

Pressure

Switch

Strain

Relief

7

Wire from 

motor

Wire from 

power

supply

8

Wire from 

motor

Wire from 

power

supply

Outside

terminal

Outside

terminal

9

Wire 

from 

motor

Wire from 

power

supply

Ground Screws

10

10.  Connect the green ground wire from the 

power supply to the remaining green 

ground screw in the pressure switch and 

re-attach the pressure switch cover.  

(

Fig. 10

)

9.  Connect the two wires from the power supply 

to the two outside terminals on the pressure 

switch. (

Fig. 9

)

8.  Thread the cable from the power supply 

through the strain relief and tighten both 

screws on the strain relief. Do not crush wire. 

(

Fig. 8

)

PUMP ELECTRICAL CONNECTIONS (CONTINUED)

Summary of Contents for CPH05S

Page 1: ...oonville IN 47601 IL0068 Integral Jet Shallow Well Pump Multi purpose Shallow Well Pump For loose missing or damaged parts or if the unit does not seem to be operating properly please call before retu...

Page 2: ...Safety and Health Act OSHA 2 Replace damaged or worn wiring cord immediately 3 Do not kink power cable and never allow the cable to come in contact with oil grease hot surfaces or chemicals 4 Wire mo...

Page 3: ...he wire size is determined by the distance from the power source to the pump motor and the horsepower rating of the motor See the wire chart on page 11 for proper wire size GENERAL PUMP INFORMATION 1...

Page 4: ...AUTION Dry fit entire assembly to ensure proper fit before gluing or taping parts CAUTION Follow all proper gluing procedures as specified by the glue manufacturer Always glue in a vertical direction...

Page 5: ...MPT x 1 4 in FPT galvanized bushing and pressure gauge optional or a pipe plug Do not tighten as you will prime your pump later at this location Fig 3 2 Install a 3 4 x 3 4 x 3 4 in galvanized tee fi...

Page 6: ...NG The pump must be properly grounded using the proper wire cable with ground WARNING Always disconnect pump from electricity before performing any work on the motor IL1380 Pressure Switch 2 L1 L2 A B...

Page 7: ...ews on the strain relief Do not crush wire Fig 4 7 Insert an electrical wire strain relief into the opening in the opposite side of the pressure switch Fig 7 Wire from motor Pressure Switch Strain Rel...

Page 8: ...ddition to the pump cavity 1 Remove the priming plug with pressure gauge and air relief plug Fig 1a with built in ejector Fig 1b with bolt on ejector 2 IL1352 Water Level in Pump Cavity 3 3 Replace ai...

Page 9: ...e connections for leaks All connections must be water and air tight in order for pump to operate PUMP PRIMING STARTUP CONTINUED Breaker Box 6 6 Turn on breaker to start pump Fig 6 IMPORTANT If the pum...

Page 10: ...h water 1 Fill pump casing 2 Suction lift too high or too long 2 Move pump closer to water source 3 Hole or air leak in suction line 3 Repair or replace Use pipe tape and pipe sealing compound 4 Foot...

Page 11: ...ewired at the factory C If pump does not run check the GFI or breaker panel switch to make it is in full operation D If the pump runs all the time make sure the pump has been primed correctly If pump...