Page 6
INSTALLING DUAL PULLEYS:
1.
Align the DUAL PULLEY bracket with the five M10
threaded inserts and install five (M10,25MM,Button
Head Bolts) and five (M10,Flat Washers) and
tighten using a 6mm hex key socket.
NUT & WASHER
BEHIND PLATE
ROUTING CABLE:
Note: The cables will come from the factory installed
from the weight stack through the dual pulley
bracket and the ends bolted to the main frame.
1.
Using a 6mm hex key socket, and a 17mm
wrench remove the (M10,50MM,Button Head
Bolt), (M10,Flat Washer), and (M10,Nut) from
the counter balance pulley.
Note: The (M10,
Nut) and (M10,Flat Washer) are located
between the pulley mounting plate and the
counter balance as shown.
After removing
the (M10,50MM,Button Head Bolt) slide the
pulley out.
2.
Using the section of cable between the dual
pulley bracket and cable end bolted to the
frame, loop the cable over the recently
removed pulley and into the pulley groove. Use
the arrows shown to assist in cable routing.
3.
Reinstall the pulley, with the cable resting in
the pulley groove, back into the pulleys original
location. Reinstall the (M10,50MM,Button
Head Bolt), (M10,Flat Washer), and (M10,Nut)
and tighten using the 6mm hex key socket, and
a 17mm wrench.
4.
Repeat steps 1 through 3 with the other
counter balance pulley and cable end.
Summary of Contents for IP-S3341
Page 1: ...LAT PULL DOWN IP S3341 INSTALLATION INSTRUCTIONS...
Page 11: ...Page 11...