3
GENERAL OPERATING
INSTRUCTIONS
- continued
3.)
Turn "ON" the Agitator Motor switch
located at the right end of the motor
housing. This switch will function only
when the Kettle switch is in the "ON"
position. If the Kettle switch is turned
"OFF", the Motor will also stop. This Motor
should always be running when there is
corn in the Kettle. This will prevent
scorching or burning of corn.
4.)
A Corn and Seasoning measuring cup
is supplied with your machine. Pour a
level measuring cup of Oil (2 ounces -
Models 49, 49D, 49SL, 59, 59D, 59SL and
3-1/2 ounces - Models 89, 89D, 89SL) in
Kettle. Add a level measuring cup of raw
corn (8 ounces - Models 49, 49D, 49SL,
59, 59D, 59SL and 14 ounces - Models
89, 89D, 89SL) and a Teaspoon of Popcorn
Salt. Vary the amount of salt and oil to
suit taste. If desired, salt may be added
adfter the Corn is popped.
5.)
When the Corn stops popping, dump
the Kettle immediately by turning the
handle clockwise approximately 90
degrees to release latch. Recharge as
quickly as possible. Screen out unpopped
kernels over the perforated section of the
Corn pan.
6.)
Turn the Kettle "OFF" when the
desired amount of popping is completed.
WARNING
Do not leave the Kettle and Motor switch
"ON" when the machine is not in use. Do
not immerse the Kettle in water or allow
water to come in contact with the Heating
element.
Popping Corn in dry kettle is not
recommended.
Do not connect machine to Direct Current,
as this unit is designed to operate on
Alternating Current only!
MAINTENANCE
Keep The Popping Unit Clean
After each popping period, wipe clean the
Kettle inside and out while it is warm.
This is important because if seasoning
and salt are not thoroughly removed, a
carbonized material will form. This
condition not only lowers popping
efficiency and causes excessive smoking,
but could damage the unit. For retaining
the high lustre on the stainless steel
Kettle shell and lids, use a non-abrasive
standard stainless steel cleaner when the
Kettle is cold. Use a damp cloth and a
warm mild soap solution to clean the glass
and clear plastic surfaces.
To remove Kettle:
Turn "OFF" the Kettle motor switches.
Disconnect the Twist Lock Cap at the end
of the Kettle conduit, turn Kettle handle
clockwise 90 degrees to unlatch the
Kettle, hold the Kettle and pull out the
hinge pin. The Kettle can now be removed
from unit. Use asbestos gloves to remove a
hot Kettle. DO NOT PLACE THE KETTLE
IN WATER, as this will damage the
electrical assembly.
To change Sign Display Lamps (on Sign
Lighted Models):
Turn "OFF" all switches. Unscrew 2 sheet
metal screws on the Rear side top (holding
switch and pilot light panel) and 4 screws
on the top. Cautiously take the top off.
Cahnge bulb(s) and reassemble the top
onto the frame. Tighten all six screws
securely. WARNING! Use only inside
Frosted Bulb. Wattage per label on the
surface of the Top Liner. By Authorized
Personnel Only.
MAINTENANCE and REPAIRS
Contact the Factory or one of its
representatives or a local Service
Company for Service or Maintenance
required.