Hard Wire Instructions
(Perm Mount Models)
CAUTION:
All wires connected to the positive terminal of the battery should be fused at the
battery for their rated load.
Testing the light before this fuse is properly installed will
void the warranty on the light.
Connect the worklight wires as follows:
BLACK
-
(Ground)
Connect to the negative side of the battery.
RED
-
(Power)
Connect to +12 VDC through your switch.
Be sure to
use a 10 amp fuse
when connecting the switch to the positive side of the power supply.
PURPLE
-
(Optional - High/Low)
Switches the light between High and Low power.
High Power Only
: Leave disconnected (cover wire with wire nut or tape).
Low Power Only
: Connect to +12VDC or Ground.
High/Low Switching Option:
Connect to 12VDC or Ground through a switch.
GREEN
- Touch and release to +12VDC or GROUND to scroll through patterns.
WHITE
-
(Synchronization)
To synchronize the flashing of multiple units, connect the white
wires from up to six units together,
ONLY AFTER PROGRAMMING
them for the
same
pattern (see
Synchronization of Multiple Lights
section on next page).
If you are only installing one unit, cut the White wire short and tape the end.
To change patterns briefly touch and release the Green wire to +12VDC.
The cycle repeats after the last pattern.
Pattern Shortcuts:
Hold the Green wire to +12VDC for the length of time that corresponds to
the pattern you would like to jump to.
After selecting a pattern, deactivate the light to store the selected pattern.
Pattern Programming
Refer to the instructions enclosed with your worklight for proper connection of those wires.
†
SAE J845 Compliant Patterns when properly configured