SPS5.1 Manual

6

2.5

Firing Displays

This is shown when a delayed start is in progress.  The display
shows the hours:minutes remaining until firing commences.

This shows that the initial ramp, ramp 1 is being fired.  For addi-
tional information press the 

Æ

 key.  This additional information

is also displayed once per minute.

This shows that the final ramp, ramp 2 is being fired.  Press the

Æ

 key for additional information.

This shows that the controller is soaking.  Press the 

Æ

 key for

additional information including the time left in soak.

This shows that the soak period is complete and that the load is
cooling naturally.  

HOT!

 is displayed flashing.

This shows that the load has cooled to less than 100°C.

This shows that the load has cooled to less than 40°C & firing is
complete.

DELAYED START...
TIME LEFT       04:32

SLOW HEATING...

à

KILN TEMP       23°C

FAST HEATING...

à

KILN TEMP      817°C

SOAKING...

à

KILN TEMP   1200°C

COOLING...   HOT!
KILN TEMP   1172°C

COOL
KILN TEMP     96°C

          READY

SPS5.1 Manual

       Page 7

2.6

Power Fail Recovery

In the event of power failure followed by power restoration, the instrument attempts to take
intelligent recovery actions to avoid a firing being aborted.  The instrument has no direct
knowledge of how long the power has been off so the recovery action taken depends on where the
instrument had reached in the firing sequence prior to power failure as detailed below:-

Before Power Failure

After Power Failure

In 

READY

 mode

Timing delayed start

On Ramp 1 approaching t1

On Ramp 2 approaching t2

In Soak Period timing Soak
Time

Cooling after SOAK period

In 

READY

 mode

Immediate start as if the end of Delay Time reached

Immediate restart.  Temperature will increase at ramp rate
1 of the current program starting at the present temperature

Immediate restart.  If present temperature greater than t1
temperature will increase at ramp rate 2 of the current
programme starting at the present temperature.  If present
temperature is less than t1 temperature will increase at
ramp rate 1 of the current program starting at the present
temperature

As above.  The full soak period of the current program will
be re-applied

Cooling continued.

Installation Category: II
Pollution Class: 2

3.0

Installation Instructions

3.1

Safety

ISOLATE

BEFORE

REMOVING

COVER

230V ~ 50HZ 1.0A

Fuse: 1.0A Anti-surge
Wickmann type TR5 T1A 250V

WARNING

                    

ISOLATE FROM ELECTRICAL SUPPLY BEFORE OPENING THIS
INSTRUMENT FOR INSTALLATION, CONFIGURATION OR REPAIR
PURPOSES

Summary of Contents for SPS5.1

Page 1: ...oller RUN HALT SET SPS 5 1 Stanton Pottery Supplies Ltd Canal Lane Westport Lake Tunstall STOKE ON TRENT Staffordshire England ST6 4NZ Tel 44 0 1782 835467 Fax 44 0 1782 812435 email sales stanton kilns co uk www stanton kilns co uk Issue 5 1E01 Date 10 July 98 Stanton Pottery Supplies Ltd Manufactured in Staffordshire U K ...

Page 2: ... wire size 1 5mm Temperature Ramp Rate to temperature t1 setting Range 20 to 240 C hour Resolution 20 C hour t1 setting Range 0 to 1310ºC Resolution 1ºC t2 setting Trim Range 0 to1310ºC Resolution 1ºC START DELAY setting Range 00 00 to 99hr 59min Resolution 1 min Control Accuracy Reading accuracy 0 25 FSD 1 digit P I D Control Cold junction compensation Environmental Operating temperature range 0 ...

Page 3: ...is switched off and an error message is displayed for one minute After this period the controller resets itself and restarts as if a power failure had occurred If the potential error has cleared the instrument will proceed as normal If the error condition persists the instrument will repeat the error display cycle In the event of an error contact the supplier quoting the error number THERMOCOUPLE ...

Page 4: ...rs which have been previously selected with the SET key Pressing this key when a firing in in progress will immediately abort the firing Pressing this key when READY is displayed enables the user to select firing parameters Pressing this key during a firing has no effect This is used to increment user input when in SET mode Pressing this key has no effect when READY is displayed or when a firing i...

Page 5: ...S5 1 K4 is Mains Live input K5 is Mains Neutral input K6 is Earth input an Earth must be fitted to this controller VR1 is the display contrast control FS1 is the protective fuse 1 0A Anti surge Wickmann type TR5 T1A 250V Farnell Electronic Components 150 988 RS Components 226 6583 SPS5 1 Manual Page 5 2 4 Setting Pressing the SET key when READY is displayed causes the cur rently selected ramp rate...

Page 6: ...actions to avoid a firing being aborted The instrument has no direct knowledge of how long the power has been off so the recovery action taken depends on where the instrument had reached in the firing sequence prior to power failure as detailed below Before Power Failure After Power Failure In READY mode Timing delayed start On Ramp 1 approaching t1 On Ramp 2 approaching t2 In Soak Period timing S...

Reviews: