STANLEY TLM65
6
EN
Technical Data
* The typical measurement uncertainty of ± 3 mm is
valid for measurements on white, diffusive, reflective
targets up to 5 m at low ambient light and moderate
temperatures. For distances greater than 5 m, the
measurement uncertainty could increase additionally
by 0.1 mm/m. In unfavourable conditions (such as
bright sunlight, targets with poor reflectivity, or high or
low temperatures) the measurement uncertainty
could further increase up to ± 4 mm for distances
below 5 m and additionally by roughly 0.15 mm/m for
distances greater than 5 m.
Message Codes
If the message
Error
does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message
InFo
appears with a
number, press the Clear button and
observe the following instructions:
Care
•
Clean the device with a damp, soft cloth.
•
Never immerse the device in water.
•
Never use aggressive cleaning agents
or solvents.
Disposal
CAUTION
Flat batteries must not be disposed of with
household waste. Care for the environ-
ment and take them to the collection points
provided in accordance with national or
local regulations.
The product must not be disposed with
household waste.
Dispose of the product appropri-
ately in accordance with the
national regulations in force in your
country.
Adhere to the national and country specific
regulations.
Product specific treatment and waste
management can be downloaded from our
homepage.
Warranty
The Stanley TLM has a two-year warranty.
For further information on this, contact
your dealer.
Subject to change (drawings, descriptions
and technical data).
General
Range
21 cm - 20 m
8’’ - 65’
Measuring accuracy*
± 3 mm
± 1/8’’
Smallest unit displayed
1 mm
1/16 in
Laser class
2
Laser type
635 nm, < 1 mW
Autom. power switch-off
after 120 s
Continuous measuring
yes
Area / Volume
yes
Dimension (H x D x W)
110 x 44 x 21 mm
4.33 x 1.73 x 0.83 in
Battery durability (2 x AAA)
up to 3000 measure-
ments
Weight
(without batteries)
71 g / 2.5 oz
Temperature range:
- Storage
- Operation
-25 to 70 °C
-13 to 158 °F
0 to 40 °C
32 to 104 °F
No.
Cause
Correction
252
Temperature too high Let device cool
down.
253
Temperature too low
Warm device up.
255
Received signal too
weak, measuring time
too long
Change target
surface (e.g. white
paper).
256
Received signal too
high
Change target
surface (e.g. white
paper).
257
Too much background
light
Shadow target area.
258
Measurement outside
of measuring range
Correct range.
260
Laser beam inter-
rupted
Repeat measure-
ment.