background image

EN

D

F

I

E
P

NL

N

S

DK

FIN

RUS

PL

GR

H

CZ

SK

LT

EST

LV

RO
BG

7

Stanley TLM 220i 773938a en

Menu functions

Setting the unit for distance measurements

The following units can  be set:

Setting the unit for tilt measurements

The following units can be set for tilt measurements:

Display illumination (

)

The brightness of the display has six levels of adjustment. Step 6 is the 

brightest and step 1 is the darkest setting.

Measuring with the tripod (

)

The reference point may be adjusted to the tripod mount if the user 
requires a measurement from the actual mounting grommit versus the 
front or back of the Stanley TLM. To do this select the 

 symbol in this 

menu item. You can switch the reference on the tripod on or off. The 
setting can be seen on the display 

.

)

We recommend that measurements are initiated using the 

 

key when using the device on a tripod in order to prevent loss of sharp-
ness.

)

The settings are reset when the device is switched off.

Beep (

)

You can switch the beep on or off.

Offset (

)

An offset adds or subtracts a specified value automatically to or from all 
measurements. This function allows tolerances to be taken into account 
(e.g. unfinished dimensions compared with finished dimensions). If you 
selected the Offset function in the menu, you can now adjust the value 
using the 

 or the 

 key. Pressing the key for longer increases the 

rate of change of the values. When you reach the desired offset value, 
confirm it with the 

 key. The display shows the appropriate symbol 

 or 

 for as long as the offset value is set.

Digital Pointfinder image black / white (

)

The display in pointfinder mode can be changed to black / white.

Distance

Area

Volume

1.1

0.0000 m

0.000 m²

0.000 m³

1.2

0.000 m

0.000 m²

0.000 m³

1.3

0.00 m

0.000 m²

0.000 m³

1.4

0.00 ft

0.00 ft²

0.00 ft³

1.5

0'00'' 

1

/

32

0.00 ft²

0.00 ft³

1.6

0'00'' 

1

/

16

0.00 ft²

0.00 ft³

1.7

0'00'' 

1

/

8

0.00 ft²

0.00 ft³

1.8

0'00'' 

1

/

4

0.00 ft²

0.00 ft³

1.9

0.0 in

0.00 ft²

0.00 ft³

1.10

1

/

32

 

in

0.00 ft²

0.00 ft³

1.11

1

/

16

in

0.00 ft²

0.00 ft³

1.12

1

/

in

0.00 ft²

0.00 ft³

1.13

1

/

4

 

in

0.00 ft²

0.00 ft³

1.14

0.000 yd

0.000 yd²

0.000 yd³

Units for tilt

2.1

+/- 0.0°

2.2

0.00%

2.3

mm/m

2.4

in/ft

Summary of Contents for TLM 220

Page 1: ...77 116...

Page 2: ...Stanley TLM 220i...

Page 3: ...1 2 5 11 3 4 7 10 6 9 12 15 13 8 14 2 1 8 7 3 4 5 6 1 7 6 5 4 3 2...

Page 4: ...ill result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor injury and or in appreciable material financial...

Page 5: ...of the person in charge of the instrument WARNING The person responsible for the instrument must ensure that the equipment is used in accordance with the instructions This person is also accountable...

Page 6: ...e protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instru...

Page 7: ...splay Remove the batteries before any long period of non use to avoid the danger of corrosion Use alkaline batteries or rechargeable batteries only Changing the reference point multifunctional endpiec...

Page 8: ...A horizontal line separates the measurement field and the result bar from one another A red triangle indicates whether the selected measuring program has a detailed display available 1 Program selecti...

Page 9: ...ntre of the list the priority of list entries starts at the top and fans out clockwise See drawing G The menu contains following items 1 Units of measurement distance 2 Units of measurement angle 3 Be...

Page 10: ...can switch the beep on or off Offset An offset adds or subtracts a specified value automatically to or from all measurements This function allows tolerances to be taken into account e g unfinished dim...

Page 11: ...as rotated through 180 4 Press the key and take the second measurement The device confirms the measurement with The tilt sensor is calibrated Operation Switching on and off Switches on the instrument...

Page 12: ...r maximum and minimum distances are shown in the display as well as the last measured value in the summary line Laser continuous Press and hold down the key when switching on the device until the char...

Page 13: ...meter Volume Press this button twice The symbol appears in the display Press this button to take the first length measurement e g length Press this button to take the second length measurement e g wid...

Page 14: ...s in the display The tilt is continuously shown as or depending on the setting Press to measure the inclination and the distance See figure L Direct horizontal distance Press this button twice and the...

Page 15: ...using Pythagoras theorem This procedure is helpful if the distance to measure can not be reached directly Make sure you adhere to the prescribed sequence of measu rement All target points must be in...

Page 16: ...ing symbol The laser is switched on Aim at the upper point 1 Press this button and trigger the measurement After the first measurement the value is adopted Triggers the measurement After the second me...

Page 17: ...u rement is taken and the value is displayed The timer can be used for all measurements Appendix Message codes All message codes are displayed with either or Error The following errors can be correcte...

Page 18: ...faces the measuring time may increase Distance measurements Measuring accuracy up to 10 m 2 standard deviation typically 1 0 mm Range use target plate from about 100 m 0 05 m to 200 m Smallest unit di...

Page 19: ...amp soft cloth Do not use aggressive cleaning agents or solutions Handle the inst rument as you would a telescope or camera Warranty The Stanley TLM 220i comes with a two year warranty from Stanley Mo...

Page 20: ...EXIT 1 1 1 2 3 1 2 3 1 2 max...

Page 21: ...Stanley TLM 220i...

Page 22: ......

Reviews: