The effective area of any vent should be ascertained
before installation.  The effect of any screen should
be allowed for when determining the effective free
area of any vent.  The air vents must be satisfactorily
fire proofed as per Building Regulations.  Joints be-
tween air vents and outside walls should be sealed
to prevent the ingress of moisture.  Existing air vents
should be of correct size and unobstructed for the ap-
pliance in use.  Air vents in internal walls should not
communicate with toilets, bathrooms or rooms con-
taining a shower.  Air vents traversing cavity walls
should include a continuous duct across the cavity.
The duct should be installed in such a manner as not
to impair the weather resistance of the cavity.

INSTALLATION ASSEMBLY

1.    Remove all the packaging from the stove.

2.    Position the stove in its final location.  Refer to 

      Sections 5, 6, 7, 8 & 13 to ensure that all the 
      requirements have been met.

3.    Attach the ashtray to the front of the stove (See

      Fig.15.

11

Fig.15

Fig.17

4.    Level the stove in all directions using the level-

      ling screws on the stove legs.

5.    Connect the fuel line to the oil control valve and 

      reset the control valve trigger as shown in 
      Fig.17.

6.    Check all joints on the fuel line for leaks upon 

      completion of the installation.

7.    Connect and seal the flue to the flue spigot.

8.    Connect the electrical supply to the stove using 

      the mains lead supplied.

FIRE LOG SETUP

1.

Place log A  with curved edge in front of the burn
pot so that the curve in the log is aligned with the
curve in the burn pot. The log should not over
hang the edge of burn pot.

2.    Place Log B, across the rear of the burn pot as 

      shown, it should be overhanging the rear of 
      the pot by approx 25mm. 

3.    Place log C and D to rest upon logs A and B as 

      shown, ensuring neither are directly over the 
      centre of the burn pot, they should be off a little 
      to each side, as if placed in the centre they could
      lead to soot formation when the burner is 
      operating at settings 5 & 6.  See Figs 18 & 18A.

If you choose to purchase the optional heat-
shield, Insert it underneath the stove aligning the
tabs on the back of the heathshield with the slots
on the bottom back panel. See Fig16. 

Fig.16

Fixing Screws

Ashtray

Summary of Contents for Tara Mk3

Page 1: ...nce is hot while in operation and retains its heat for a long period of time after use Children aged or infirm persons should be supervised at all times and should not be allowed to touch the hot work...

Page 2: ...lues or Chimneys 9 16 Use of External Flues 9 17 Flue Termination Height 10 18 Flue Stabilizer 10 19 Ventilation Combustion Air Requirement 10 20 Installation Assembly 11 21 Fire Log Setup 11 22 Commi...

Page 3: ...oat use disposable protection Installation should be carried out in a well ventilated area Any alterations to this appliance that are not approved in writing by Waterford Stanley will render the guara...

Page 4: ...at the maximum permitted oil flow rate This appliance has been tested and approved to EN1 flued oil stoves with vaporizing burners Appliance Class 2b All technical data are taken under laboratory con...

Page 5: ...12 inches to the front Note The hearth must be level stable and capable of supporting the stove ELECTRICAL SUPPLY All wiring external to the appliance must conform to the current B S 7671 UK B S 7462...

Page 6: ...rewed joints must only be made with taper threads complying to B S 1740 Part 1 1971 Jointing materials must be of types intended for use with oil fuel Special petroleum resisting compounds and PTFE ta...

Page 7: ...er and control valve A suitable shut off valve should be fitted near the stove and be accessible at all times NOTE Fuel to the appliance should be gravity fed only 7 These requirements are in accordan...

Page 8: ...do so could result in loss in performance of the stove WARNING Only operate this appliance if connected to a properly installed flue system This stove must be connected to a 125mm 5 diam eter flue sys...

Page 9: ...RNAL FLUES OR CHIMNEYS When connecting the stove to an existing chimney or internal flue the flue system must adhere to all the fol lowing requirements See Fig 11 1 The horizontal flue section exiting...

Page 10: ...upply to the flue whenever the flue s negative pressure reaches its upper limit and so pre vents the negative pressure in the stove rising above its optimum level The flue stabiliser should be ad just...

Page 11: ...Level the stove in all directions using the level ling screws on the stove legs 5 Connect the fuel line to the oil control valve and reset the control valve trigger as shown in Fig 17 6 Check all joi...

Page 12: ...perature i e at maximum setting adjust the draught regulator until the desired flame pattern is achieved 5 Using the flue sampling point See Fig 19 check that the Bacharach smoke number is not greater...

Page 13: ...op of oil falls into the vessel 3 Measure the oil flow for 5 minutes Consult the Technical Data section for the correct rate 4 Turn the control valve to 1 and repeat the above procedure 5 If either of...

Page 14: ...X 26 HOLD BRACKET F01142AXX 27 BOTTOM SHIELD SUPPORT BKT F01095AXX 28 SPACER V00033AXX 29 AIR WASH KNOB U00077AXX 30 TERRY CLIP W00921AXX 31 ISOLATING TRANSFORMER G00506AXX 32 STRAIN RELIEF CABLE GLAN...

Page 15: ...ustible materials and soft furnishings well away from the stove See Clearance to Combustibles section WARNING Unauthorised modification of the stove will void the product warranty Do not tamper with t...

Page 16: ...es on setting no 2 the control lever can be adjusted to setting no 4 The flame should be allowed to sta bilise at setting no 4 for another 10 minutes prior to adjusting the control to setting No 6 Max...

Page 17: ...t the draught stabiliser as it will effect the performance of the stove CO ALARM Waterford Stanley recommend the fitting of a CO Alarm in the same room as the appliance Further guidance on the install...

Page 18: ...ly with a soapy damp cloth followed by a polish with a clean dry duster 2 For stubborn deposits a soap impregnated pad can be carefully used on the vitreous enamel 3 Use only products recommended by t...

Page 19: ...locked Bleed fuel line Excessive flame noise Incorrect chimney draught Check joint seals increase height of chimney adjust draught regulator Incorrect fuel input rate Check fuel input rates adjust if...