The Laser Does Not Turn On

• 

Check the AA batteries to make sure:

• 

Each battery is installed correctly, according to (+) and (–) 

listed inside the battery compartment

.

• 

The battery contacts are clean and free of rust or corrosion.

• 

The batteries are new, high-quality, name brand batteries 

to reduce the chance of battery leakage.

• 

Make sure the AA batteries are in proper working condition. If 

in doubt, try installing new batteries.

• 

When using rechargeable batteries, make sure the batteries 

are fully charged.

• 

Be sure to keep the laser dry.

• 

If the laser unit is heated above 120 ˚F (50 ˚C), the unit will 

not turn ON. If the laser has been stored in extremely hot 

temperatures, allow it to cool. The laser level will not be 

damaged by using the Power/Transport Lock switch before 

cooling to its proper operating temperature.

The Laser Beams Flash

When in self-leveling mode, the lasers are designed to self-

level up to an average of 4° in all directions. If the laser is tilted 

so much that the internal mechanism cannot level itself (or the 

laser is not level when in 

manual mode

), the laser beams will 

flash indicating that the tilt range has been exceeded.
THE FLASHING BEAMS CREATED BY THE LASER ARE 

NOT LEVEL OR PLUMB AND SHOULD NOT BE USED 

FOR DETERMINING OR MARKING LEVEL OR PLUMB. Try 

repositioning the laser on a more level surface.

The Laser Beams Will Not Stop Moving

The laser is a precision instrument. Therefore, if it is not 

positioned on a stable (and motionless) surface, the laser will 

continue to try to find level. If the beam will not stop moving, try 

placing the laser on a more stable surface. Also, try to make 

sure that the surface is relatively flat and level, so that the laser 

is stable.

Service and Repairs

Note: Disassembling the laser level will void all warranties on 

the product.

To assure product SAFETY and RELIABILITY, repairs, 

maintenance and adjustment should be performed by 

authorized service centers. Service or maintenance performed 

by unqualified personnel may result in a risk of injury. To locate 

your nearest STANLEY

 

service center, go to http://www.

STANLEY.com.

Specifications

STHT77498

STHT77499

Light Source

Laser diodes

Laser Wavelength

630 – 680 nm visible

510 – 530 nm visible

Laser Power

≤1.5 mW CLASS 2 LASER PRODUCT

Working Range

33

 (10m)

50

 (15m)

Accuracy

±0.25” @ 33

 (±6 mm @ 10m)

Power Source

2 AA (1.5V) size batteries (3V DC)

Operating Temperature

14°F to 104°F (-10°C to 40°C)

Storage Temperature

-5°F to 140°F (-20°C to 60°C)

Summary of Contents for STHT77498

Page 1: ...STHT77498 STHT77499 Self Leveling Cross line Laser KR E Please read these instructions before operating the product www STANLEYTOOLS co kr...

Page 2: ...A English 9 16...

Page 3: ...A 1 2 4 _ 3 Figures...

Page 4: ...C B 1 4 20 D...

Page 5: ...D 1 2 45 90 a b a _ ft 9m Figures...

Page 6: ...1 2 3 E b a c b a b _ a b ft 9m F...

Page 7: ...1 2 F a a b Figures ft 1 5m...

Page 8: ...1 4 20 360 1 7 5 2 4 3 6 8 G Co L U B I T C U M T S S La The prod be us proje Us Saf The signa symb NO wh If y...

Page 9: ...instructions Failure to follow the warnings and instructions in this manual may result in serious personal injury SAVE THESE INSTRUCTIONS WARNING Laser Radiation Exposure Do not disassemble or modify...

Page 10: ...e of drugs alcohol or medication A moment of inattention while operating the laser may result in serious personal injury Use personal protective equipment Always wear eye protection Depending on the w...

Page 11: ...hecking Laser Accuracy The laser tools are sealed and calibrated at the factory It is recommended that you perform an accuracy check prior to using the laser for the first time in case the laser was e...

Page 12: ...ween a and c 30 9m 15 32 12mm 40 12m 9 16 14 4mm 50 15m 23 32 18mm Vertical Beam Plumb Checking the vertical plumb calibration of the laser can be most accurately done when there is a substantial amou...

Page 13: ...wise to lock the bracket arm in place 3 Use the bracket s clamp Figure G 6 to hold the laser in place on a stud ceiling grid or pole If necessary rotate the clamp so it is positioned at the correct an...

Page 14: ...gned to self level up to an average of 4 in all directions If the laser is tilted so much that the internal mechanism cannot level itself or the laser is not level when in manual mode the laser beams...

Page 15: ...Wavelength 630 680 nm visible 510 530 nm visible Laser Power 1 5 mW CLASS 2 LASER PRODUCT Working Range 33 10m 50 15m Accuracy 0 25 33 6 mm 10m Power Source 2 AA 1 5V size batteries 3V DC Operating Te...

Page 16: ...you have any questions or comments about this or any STANLEY tool go to http www STANLEY com WARNING Read and understand all instructions Failure to follow the warnings and instructions in this manual...

Page 17: ...inor or moderate injury NOTICE Indicates a practice not related to personal injury which if not avoided may result in property damage If you have any questions or comments about this or any STANLEY to...

Page 18: ...KR 18 OFF A 2 1 0 2 A 1 A 3 3 4 4 9m 30 1 D 1 2 A 3 3 45 4 a 5 a 90 D 2 6 b 7 a b...

Page 19: ...1 2 A 3 3 9m 30 a b 4 E 2 5 6 b 7 a c E 3 8 a c 9 a b a c a b a c 9m 30 12mm 15 32 12m 40 14 4mm 9 16 15m 50 18mm 23 32 30 9m 1 1 5 m 5 ft F 1 2 A 3 3 4 a 5 F 2 6 a b 7 a b 8 D a b D a b 2 5m 8 3 5mm...

Page 20: ...es a potentially hazardous situation which if not avoided may result in minor or moderate injury NOTICE Indicates a practice not related to personal injury which if not avoided may result in property...

Page 21: ...KR 21 STANLEY AA AA 50 C 120 F 4 STANLEY http www STANLEYTOOLS co kr...

Page 22: ...STHT77499 630 680 nm 510 530 nm 1 5 mW 2 10m 33 15m 50 6 mm 10m 0 25 33 2 AA 1 5V 3V DC 10 C 40 C 14 F 104 F 20 C 60 C 5 F 140 F N474562 B052R299 6001 LR6 1 5V Changzhou Anyida Power Technology Co Ltd...

Page 23: ...23 Notes...

Page 24: ...STANLEY TOOLS 701 East Joppa Road Towson Maryland 21286 N551879 November 2017 http www STANLEY com 2018 STANLEY TOOLS 701 East Joppa Road Towson Maryland 21286 N593610 2018 05 http www STANLEYTOOLS c...

Reviews: