26 ► SRP 2240 / 3860
User Manual
TROUBLESHOOTING
General Information
Fault Table
Possible cause
Remedy
Remarks
Engine does not start
Speed control lever in «STOP»-position
No fuel
– Tank run dry
– Fuel filter blocked
– Fuel valve «OFF»
– Defective feed pump
Oil pressure lost
Compression too low
Engine switch «OFF»
Choke «OPEN»
Spark plug faulty, fouled or improperly
gapped
Spark plug wet with fuel (flooded engine)
Set lever to «START»-position
Add fuel
Renew fuel filter
Move lever to «ON» position
Function must be checked
Check engine oil level
Contact a Stanley-service center
Turn engine switch to «ON» position
Move lever to «CLOSE» position
Gap or replace spark plug
Dry and reinstall spark plug
HONDA
HONDA
HONDA (Unless the engine is warm)
HONDA
HONDA (Start engine with throttle
lever in «MAX» position)
Engine stops by itself during regular operation
Fuel supply is interrupted
– Tank run dry
– Fuel filter blocked
– Defective feed pump
Oil pressure lost
Mechanical defects
Add fuel
Renew fuel filter
Function must be checked
Check engine oil level
Contact a Stanley-service center
Reduced engine performance
Fuel supply is obstructed
– Tank run dry
– Fuel filter blocked
– Tank venting is inadequate
– Leaks at pipes unions
Air cleaner blocked
Incorrect valve clearance
Too much oil in engine
Too much oil in exciter
Default in hydraulic system
Add fuel
Renew fuel filter
Ensure that tank is adequately vented
Check threaded pipe unions
Remove dirt from air cleaner
Adjust valve clearance
Correct the engine oil level
Check exciter oil level
Contact a Stanley-service center
Engine runs, machine does not move forward
Insufficient V-belt tension
V-belt broken
Centrifugal clutch lining worn
Too much oil in exciter
Default in hydraulic system
Retention V-belt
Replace V-belt
Replace linings and springs
Check exciter oil level
Contact a Stanley-service center
• Observe the safety information
• Only qualified and authorised persons may carry out
repair work (mechanics specialising in construction and
agricultural machinery).
• In case of faults, the operating and maintenance instruc-
tions must be referred to for correct operation and main-
tenance.
• If the cause of the fault cannot be located or remedied, an
authorised Stanley Service Center should be contacted.
• Always first check the most likely causes (fuses,
LEDs, etc.).