Operation
Meaning
Check the
installation.
Please check the installation regularly (one month), to
avoid any decline or damage to the unit which may hurt
people or damage the unit.
Switch off the
power.
Please switch off the power when cleaning or maintenance.
Prohibition
It is prohibited to use copper or iron as fuse. The correct
fuse must be fixed by electrician for the heat pump.
Prohibition
It is prohibited to spray the flammable gas to the heat
pump, as it may cause fire.
3.
Features
With new technology of DC Inverter EVI, Solis Eco Monoblock
Series can be used in extremely cold area for heating/cooling, hot water. The Series is featured as follows.
3.1. DC Inverter EVI Heat Pump Technology
a. Ruking Driver Board
Ruking driver board controls the compressor running precisely basing on water temperature and air temperature.
And it can work with wide voltage of 456V at maximum.
b. Panasonic Inverter Compressor
Panasonic inverter EVI compressor is adopted for the units to ensure high stability.
c. DC Fan Motor
DC fan motor with adjustable speed ensures the units’ silent running. This makes the units work more efficiently at
different conditions.
3.2. A+++ Energy Level
Solis Eco Monoblock DC inverter technology enables the heat pump to adjust its frequency from 30Hz - 90Hz
according to real heating requirement. With this technology, Solis Eco Monoblock Series achieve an energy level of
A+++ according to ErP directive.