10
Test
Action
Observation
Controller
Reader
Tamper and
Override Test
Remove the link between
TAMP
and
0V
on
the
Tamper & Override
terminal block.
The auxiliary relay is activated but the door relays are
unaffected.
Remove the link between
OVRD
and
0V
on
the
Tamper & Override
terminal block.
Both auxiliary and lock relays are activated, the door opens
and the lock operates.
RS-232 Test -
PAC 512 only
Link
Tx
and
Rx
on the
RS-232
terminal block.
The red and
green RS-232
LEDs are lit.
There is no effect
at the reader.
Leave One
-Touch™ Active
Test mode
Hold down the
One-Touch™
button for less
than 2 seconds.
One-Touch™ Test
mode will
automatically time out after 1 hour and on
power down and up.
The green
system status
LED returns to its
normal flash rate
The reader LED
returns to its
normal operation.