F
AUL
T
CAUSE
POSSIBLE REMEDY
Pilot will not light
V
arious
Refer to Ignition
Functional Check 1
No S
p
ark
V
arious
Refer to Ignition
Functional Check 2
Pilot will not st
ay lit or goes
V
arious
Refer to Flame Failure
out in use
Check 2-
S
tove goes out while
Flue blockage
Insuf
ficient flue pull or
warming or in operation
Sensor has been activated
p
artial blockage - flue must be
checked by an engineer
.
Uneven flame p
attern
Ceramics not
Check front coal and flame
positioned correctly
baf
fle are positioned as shown
in Section 7.
Coals not laid correctly
The coals may require slight
adjustment, see Section 7.
Debris in burner
Clean burner port
s, refer to
port
s
Users Manual for guidance.
Blue Flame
W
arming Up
S
tove will burn blue until run
ning temperature has been
achieved - typically 20 minutes.
Aeration plate
Ensure that the aeration plate
is tight and sit
s flat.
Insuf
ficient gas pressure
Check the gas pressure and
correct if necessary
.
Airbox QC label removed
Ensure QC seal on front of air-
box is correctly sealed.
Low flame height
Blockage in supply pipe
Disconnect pipe and purge,
ensure no debris has entered
the stove pipework.
Blocked gas filter
Replace filter - refer to
Section 12
Insuf
ficient gas pressure
Check the gas pressure and
correct if necessary
.
Empty supply t
ank or
LPG only - ensure adequate
clylinder
supply of gas in cylinders.
Short pilot flame length (see
Insuf
ficient gas
Check the gas pressure and
diagram 26)
pressure
correct if necessary
.
Blocked pilot flame
Replace Unit - refer to section 10
IGNITION FUNCTIONAL
CHECK 1
PILOT
WILL
NOT
LIGHT
Ensure there is no debris around the pilot assembly e.g. coal, soot, etc
which could short the sp
ark, clean the area.
There is a blockage in the system, check the inlet test point, the mag
seating, valve and pilot filter
.
Operate the valve.
Is there a sp
ark?
Is the control being
operated correctly?
Consult users book
and retry
Will the pilot light
with a match?
Is the gas turned on to
the appliance?
Check isolation t
ap and
gas meter
, retry
Correct and retry
.
Is the gas pressure
correct?
Has the system got any
air in it?
Purge the gas pipes
and retry
.
GO T
O
THE
NEXT
CHAR
T
IGNITION
FUNCTIONAL
CHECK
SYSTEM OK
Ensure gap between
electrode and thermo-
couple is 3.5mm and
retry
. If the gap is OK
then first change the
ignition lead and retry
, if
still no good then change
the piezo.
Does the pilot light?
YES
YES
NO
NO
YES
YES
YES
NO
YES
NO
NO
NO
YES
NO
8