HG80 User
Manual ◄ 13
Problem
Cause
Solution
Grinder does not run.
Hydraulic power source not
functioning.
Check power source for proper flow
and pressure (7–10 gpm/26–38 lpm @
1500–2000 psi/105–140 bar.
Couplers or hoses blocked.
Locate and remove restriction.
Hydraulic motor failure.
Inspect and repair.
Hydraulic lines not connected.
Connect lines.
Grinder operates too slow.
Hydraulic motor speed to slow.
Check power unit for proper flow (7–10
gpm/26–38 lpm).
High back-pressure.
Check hydraulic system for excessive
back-pressure (over 250 psi/17 bar).
Couplers or hoses blocked.
Locate and remove restriction.
Oil too hot (above 140 °F/60 °C)
or too cold (below 60 °F/16 °C).
Check hydraulic power source for
proper oil temperature. Bypass
cooler to warm oil or provide cooler to
maintain proper temperature.
Relief valve set too low.
Adjust relief valve to 2100–
2250psi/145–155 bar.
Hydraulic motor worn.
Inspect, repair or replace.
Flow control malfunctioning.
Have flow control serviced at an
authorized Stanley service center.
Grinder operates too fast.
Flow control malfunctioning.
Have flow control and valve body
serviced at an authorized Stanley
service center.
If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem.
When diagnosing faults in operation of the grinder, always check that the hydraulic power source is supplying the
correct hydraulic flow and pressure to the grinder as listed in the table. Use a flowmeter known to be accurate.
Check the flow with the hydraulic oil temperature at least 80
°
F/27
°
C.
TROUBLESHOOTING
Summary of Contents for HG80