8
ENGLISH
(Original instructions)
indicating that the charging process has started.
u
The completion of charge will be indicated by the green
charging light (8a) remaining ON continuously. The battery
pack (6) is fully charged and may be removed and used at
this time or left in the charger (8).
u
Charge discharged batteries within 1 week. Battery life will
be greatly diminished if stored in a discharged state.
Charger LED Modes
Charging:
Green LED Intermittent
Fully Charged:
Green LED Solid
Hot/Cold Pack Delay:
Green LED Intermittent
Red LED Solid
Note:
The compatible charger(s) will not charge a faulty
battery pack. The charger will indicate a faulty battery pack by
refusing to light.
Note:
This could also mean a problem with a charger. If the
charger indicates a problem, take the charger and battery
pack to be tested at an authorized service centre.
Leaving the battery in the charger
The charger and battery pack can be left connected with the
LED glowing indefinitely. The charger will keep the battery
pack fresh and fully charged.
Hot/Cold Pack Delay
When the charger detects a battery that is too hot or too
cold, it automatically starts a Hot/Cold Pack Delay, the green
LED (8a) will flash intermittently, while the red LED (8b) will
remain on continuously, suspending charging until the battery
has reached an appropriate temperature. The charger then
automatically switches to the pack charging mode. This
feature ensures maximum battery life.
Battery state of charge indicator (Fig. B)
The battery includes a state of charge indicator to quickly
determine the extent of battery life as shown in figure B. By
pressing the state of charge button (6a) you can easily view
the charge remaining in the battery as illustrated in figure B.
Installing and Removing the Battery Pack from
the tool
Warning!
Make certain the lock-off button is engaged to
prevent switch actuation before removing or installing battery.
To install battery pack (Fig. C)
u
Insert battery pack firmly into tool until an audible click is
heard as shown in figure C. Ensure battery pack is fully
seated and fully latched into position.
To remove battery pack (Fig. D)
u
Depress the battery release button (6b) as shown in
figure D and pull battery pack out of tool.
Belt hook (Optional extra) (Fig. E, F)
Warning!
To reduce the risk of serious personal injury,
place the forward/reverse button in the lock-off position or
turn tool off and disconnect battery pack before making
any adjustments or removing/installing attachments or
accessories. An accidental start-up can cause injury.
Warning!
To reduce the risk of serious personal injury, ONLY
use the tool’s belt hook (9) to hang the tool from a work belt.
DO NOT use the belt hook (9) for tethering or securing the
tool to a person or object during use. DO NOT suspend tool
overhead or suspend objects from the belt hook.
Warning!
To reduce the risk of serious personal injury, ensure
the screw (10) holding the belt hook is secure.
Note:
When attaching or replacing the belt hook (9), use only
the screw (10) that is provided. Be sure to securely tighten
the screw.
The belt hook (9) can be be attached by sliding into the
slots (11) on either side of the tool using only the screw (10)
provided, to accommodate left- or right- handed users. If the
hook is not desired at all, it can be removed from the tool.
To move the belt hook, remove the screw (10) that holds the
belt hook (9) in place then reassemble on the opposite side.
Be sure to securely tighten the screw (10).
Note:
Various trackwall hooks and storage configurations
are available.
Please visit our website www.stanley.eu/3 for
further information.