11
GB
Horizontal Beam - Scan Direction
Checking the horizontal scan calibration of the laser requires
two walls 9m (30
′
) apart. It is important to conduct a calibration
check using a distance no shorter than the distance of the
applications for which the tool will be used.
1.
Place the laser against the end of a
9m (30
′
)
wall
(Figure
E
#1).
2.
Turn
the laser ON.
3.
Press
once to display a horizontal laser beam
.
4.
Turn the laser toward the opposite end of the wall and
parallel to the adjacent wall.
5.
At least
9m (30
′
) apart on the laser beam, mark
a
and
b
.
6.
Turn the laser 180º.
7.
Adjust the height of the laser so the center of the beam is
aligned with
a
(Figure
E
#2).
8.
Directly above or below
b
, mark
c
along the laser beam
(Figure
E
#3).
9.
Measure the vertical distance between
b
and
c
.
10.
If your
measurement is greater than the
Allowable
Distance Between
b
and
c
for the corresponding
Distance Between Walls
in the following table, the laser
must be serviced at an authorized service center.
Distance
Between Walls
Allowable Distance
Between
b
and
c
9m (30
′
)
6mm (1/4”)
12m (40
′
)
8mm (5/16”)
15m (50
′
)
10mm (13/32”)
Horizontal Beam - Pitch Direction
Checking the horizontal pitch calibration of the laser requires
a single wall at least 9m (30
′
) long. It is important to conduct
a calibration check using a distance no shorter than the distance
of the applications for which the tool will be used.
1.
Place the laser against the end of a
9m (30
′
)
wall
(Figure
F
#1).
2.
Turn
the laser ON.
3.
Press
once to display a horizontal laser beam
.
4.
Turn the laser toward the opposite end of the wall and
parallel to the adjacent wall.
5.
At least
9m (30
′
) apart on the laser beam, mark
a
and
b
.
6.
Move the laser to the opposite end of the wall
(Figure
F
#2).
7.
Position the laser toward the first end of the same wall and
parallel to the adjacent wall.
8.
Adjust the height of the laser so the center of the beam is
aligned with
b
.
9.
Directly above or below
a
, mark
c
along the laser beam
(Figure
F
#3).
10.
Measure the distance between
a
and
c
.
11.
If your measurement is greater than the
Allowable
Distance Between
a
and
c
for the corresponding
Distance Between Walls
in the following table, the laser
must be serviced at an authorized service center.
Distance Between
Walls
Allowable Distance
Between
a
and
c
9m (30
′
)
6mm (1/4”)
12m (40
′
)
8mm (5/16”)
15m (50
′
)
10mm (13/32”)
Vertical Beam - Plumb
Checking the vertical (plumb) calibration of the laser can be
most accurately done when there is a substantial amount of
vertical height available, ideally 9m (30
′
), with one person on
the floor positioning the laser and another person near a ceiling
to mark the position of the beam. It is important to conduct
a calibration check using a distance no shorter than the distance
of the applications for which the tool will be used.
1.
Place the laser on a smooth, flat, stable surface that is
level in both directions (Figure
G
#1).
2.
Turn
the laser ON.
3.
Press
three times to display the front and side vertical
beams.
4.
Press
twice to display the down dot
.
5.
On the level surface, mark the position of the down dot
a
(Figure
G
#2).
Summary of Contents for FATMAX FMHT1-77416
Page 2: ...Figures 2 1b 1a 2 A 1 3 4 5 6 7 5 5 ...
Page 3: ...3 C B 1 4 20 5 8 11 1 2 D ...
Page 4: ...Figures 4 a b c b a b D c a b a 30 9m _ E 3 2 1 ...
Page 5: ...5 1 2 F a b c a b b a c b D 30 9m _ c a c 3 ...
Page 6: ...Figures 6 2 G a b c 8 2 5m _ F 1 e b c a d d b c e 3 ...
Page 7: ...7 1 2 3 H D D D 90 c c c f a a f a b a e e 10 3m _ 10 3m _ 10 3m _ b b ...
Page 211: ...211 Notes ...