CODE POSSIBLE CAUSE
POSSIBLE SOLUTION
23
Paint spray on internal motor parts
Contact a Stanley Tools factory service center or a Stanley Tools authorized
service center. Do not operate the compressor in the paint spray area. See
flammable vapor warning.
24
Fuse blown, circuit breaker tripped
1. Check fuse box for blown fuse and replace as necessary. Reset circuit
breaker. Do not use a fuse or circuit breaker with higher rating than that
specified for your particular branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension cord.
4. Disconnect the other electrical appliances from circuit or operate the
compressor on its own branch circuit.
25
Tank pressure exceeds pressure switch
cut-
in
pressure
Motor will start automatically when tank pressure drops below
cut-in
pressure of pressure switch.
26
Pressure release valve on pressure switch
has not unloaded head pressure
Set the On/Off switch to OFF. If the valve does not open, replace switch.
Contact
a Stanley Tools factory service center or a Stanley Tools authorized
service center.