background image

7 • AL32 FATMAX

6

7

12

13

4

11

10

8

9

1

2

3

5

5

A

B

C

A

B

C

A

B

O

32X AUTOMATIC LEVEL KIT

AL32

6

7

12

13

4

11

10

8

9

1

2

3

5

5

A

B

C

A

B

C

A

B

O

32X AUTOMATIC LEVEL KIT

AL32

6

7

12

13

4

11

10

8

9

1

2

3

5

5

A

B

C

A

B

C

A

B

O

32X AUTOMATIC LEVEL KIT

AL32

6

7

12

13

4

11

10

8

9

1

2

3

5

5

A

B

C

A

B

C

A

B

O

32X AUTOMATIC LEVEL KIT

AL32

6

7

12

13

4

11

10

8

9

1

2

3

5

5

A

B

C

A

B

C

A

B

O

32X AUTOMATIC LEVEL KIT

AL32

Fig. 3

Fig. 4

Fig. 

Fig. 

Fig. 7

Summary of Contents for FatMax AL32

Page 1: ...AL32 FATMAX BUL SL SI A B 32X AUTOMATIC LEVEL KIT AL32 5 A 32X AUTOMATIC LEVEL KIT AL32 1 77 238 241 ...

Page 2: ... AL32 FATMAX 12 13 6 7 4 11 10 8 9 1 2 3 5 A B C A B C Fig 1 Fig 2 ...

Page 3: ...ock protects instrument during transport or storage the lock can also be used as a handy compensator checking tool Large effective aperture and minimum focus of 0 3 m Top mounted optical peep sight for quick reference Large easy to use precise focusing knob Easy to read horizontal circle Penta prism for easy bubble viewing Sealed dust protected leveling screws Water resistant sealed construction p...

Page 4: ...ets The new readings should agree with the first readings If the new readings do not agree you should have the instrument checked by a STANLEY Authorized Repair Center or try the Line of sight adjustment USING THE INSTRUMENT Setting up the instrument and centering the bubble 1 Set up the tripod and attach the level using the tripod mounting screw 2 Adjust the tripod legs until the tripod head is r...

Page 5: ... and 1 038 m The stadia ratio is 1 100 therefore the distance from the instrument to the rod is 1 352 1 038 x 100 31 41 m Angle measurement As shown in Fig 5 sight point A and rotate the horizontal circle until the reference mark is on 0 Rotate the level and sight point B the reference mark will indicate the angle between A and B CALIBRATION Your AL32 Automatic Level has been factory calibrated ho...

Page 6: ...between two leveling rods set approximately 30m to 50m apart Sight rods A and B the height readings are a1 and b1 Fig 10 The value H is equal to a1 b1 Move the instrument to within 6 feet 2m of rod A and re level Again sight rods A and B these height readings are a2 and b2 Fig 11 If a1 b1 a2 b2 H the line of sight is horizontal If not the level should be adjusted as follows Because the instrument ...

Page 7: ...has stopped working effectively bake it to remove moisture or replace with a new bag TECHNICAL DATA Telescope Erect Telescope length 8 3 210 mm Magnification 32 x Leveling accuracy 1 16 250 1 6 mm at 75 m Working range 350 107 m Clear objective aperture 40mm Field of view 1 5 Shortest focusing distance 1 0 3m Stadia ratio 100 Stadia addition 0 Water resistant Yes Compensator Leveling range 15 Sett...

Page 8: ...d by Stanley Tools Repair or replacement under this Warranty does not affect the expiry date of the Warranty To the extent permitted by law Stanley Tools shall not be liable under this Warranty for indirect or consequential loss resulting from deficiencies in this product This Warranty may not be varied without the authorisation of Stanley Tools This Warranty does not affect the statutory rights o...

Page 9: ...176 AL32 FATMAX A B O A B C A B C 12 13 4 11 10 A B C A B C B A B O 11 10 1 2 3 5 A C A B O Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 ...

Page 10: ...AL32 FATMAX 177 A B O O A B O Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 ...

Page 11: ...178 AL32 FATMAX 2007 THE STANLEY WORKS www stanleyworks com Stanley Works Benelux Egide Walsschaertsstraat 14 16 2800 Mechelen Belgium Issue 1 04 08 ...

Reviews: