8 ► CD12
User Manual
Oil Flow
Hose Lengths
Inside Diameter
USE
(
Press/Return)
Min. W
orking Pressure
GPM
LPM
FEET
METERS
INCH
MM
PSI
BAR
Certifi
ed Non-Conductive Hose - Fiber Braid - for Utility Bucket T
rucks
4-9
15-34
up to 10
up to 3
3/8
10
Both
2250
155
Conductive Hose - W
ire Braid or Fiber Braid -DO NOT USE NEAR ELECTRICAL
CONDUCT
ORS
4-6
15-23
up to 25
up to 7.5
3/8
10
Both
2500
175
4-6
15-23
26-100
7.5-30
1/2
13
Both
2500
175
5-10.5
19-40
up to 50
up to 15
1/2
13
Both
2500
175
5-10.5
19-40
51-100
15-30
5/8
16
Both
2500
175
5-10.5
19-40
100-300
30-90
5/8
16
Pressure
2500
175
3/4
19
Return
2500
175
10-13
38-49
up to 50
up to 15
5/8
16
Both
2500
175
10-13
38-49
51-100
15-30
5/8
16
Pressure
2500
175
3/4
19
Return
2500
175
10-13
38-49
100-200
30-60
3/4
19
Pressure
2500
175
1
25.4
Return
2500
175
13-16
49-60
up to 25
up to 8
5/8
16
Pressure
2500
175
3/4
19
Return
2500
175
13-16
49-60
26-100
8-30
3/4
19
Pressure
2500
175
1
25.4
Return
2500
175
Figure 1.
Typical Hose Connections
Tool to Hydraulic Circuit Hose Recommendations
The
chart
to
the
right
shows
recommended
minimum hose diameters
for
various
hose lengths based
on gall
ons per minute
(GPM)/liters
per
minute
(LPM).
These
recommendations
are
intended
to
keep
return
line
pressure
(back
pressure
)
to
a
minimum
acceptable
level
to ensure
maximum
tool
performance.
This chart
is intended to
be used for
hydraulic
tool applications only based on ST
ANLEY
tool
operating
requirements
and
should
not
be
used for any other applications.
All hydraulic hose must
have at
least a
rated
minimum
working
pressure
equal
to
the maximum hydraulic system relief valve setting.
All hydraulic hose must meet or exceed specifi
cations as set forth by SAE J517.
HOSE RECOMMENDATIONS
Summary of Contents for CD12
Page 2: ......
Page 17: ...CD12 User Manual 17 CD12 PARTS ILLUSTRATION 220 Valve Assy 209 Water Valve Hose Assy 65204 ...
Page 19: ...CD12 User Manual 19 CD12 ANCHOR STAND ILLUSTRATION ...
Page 21: ......
Page 22: ......
Page 23: ......