NOTE:  The fan flue assembly is suit-

able for a 275mm (11”) wall and cannot

be reduced, or extended if it is installed

through a wall less than 275mm (11”)

the terminal will protrude accordingly

and must have fitted a suitable terminal

guard.

Fig.7

NON STANDARD WALL THICKNESS

There is an extended flue assembly available (to

order) that is suitable to be installed through wall

thickness of 368mm (14.5”) 444mm (17.5”) 495mm

(19.5”) and a maximum of 558 (22”).

To reduce the length of the assembly from the max-

imum of 550 (22”) wall thickness, undo the band

retaining the end reducer and remove the reducer 

taking care that no damage occurs.  Select the thick-

ness required and cut through the assembly on the

inner most of the paired groves.  Care must be taken

to cut straight and to remove all sharp edges.  Place

the reducer in position at the inner most end of the

flue assembly and fix into position by re-locating the

band on the remaining grove and lock into place.

Install the air duct as normal cutting the flexible liner

to the correct length in accordance with the wall

thickness.

CONTENTS OF KIT:

1.

Fan flue terminal.

2.

Terminal Guard.

3.

Fixing Brackets.

4.

Primary air inlet spigot.

5.

Air inlet duct.

6.

Air Inlet terminal.

7.

Jubilee clips.

8.

M6 Nuts and Bolts (4 No)    

10. Junction box and flexible cable tubing.

11. Burner connection cable.

IMPORTANT.

Fan Flue Terminal Kit is

NOT

to be  connected to

an appliance burning 35 Sec. class D fuel.