background image

SSS-SEDA (Emergency Door Alarm)

Installation Instructions

NOTE:
SEDA Door Sensors are provided to match the door width provided.

INSTALLATION INSTRUCTIONS:

FULL MORTISE HINGE
See Separate sheet provided for installation instructions.

POWER SUPPLY / CONTROLLER
Install the Power Supply / Controller. Connect console to it. Power up the controller. 
All LED’s should turn green. Install each door individually as follows

STROBE
Mount on ceiling and run wires to Controller.
Observe Polarity Red “+” and Black “-“.

KEY SWITCH
Add mortise cylinder (straight Yale cam). 
Mount on single gang box at door and run wires to Controller. Key switch is “NC”, system can not work without it.

DOOR SENSOR
Please Read Completely Before Starting

1) Mark a horizontal line ¾” from the top of the door and extend to 
the lock edge of the door as shown in            . 

2) Mark a vertical line 1-1/8" from the notched edge of the hinge as
shown in             .

3) Mark center point at horizontal and vertical line intersects. Drill 
pilot hole of 1/8" as shown in            .

4) Loosen sensor cover screws enough to enable removal of the sensor cover form the mounting plate.  
Loosen sensor adjustment nuts.

5) Place sensor mounting plate on the door with first mounting hole over pilot hole as shown in            . Pull 
out wire from wiring hole.

6) Temporarily secure the hinge side sensor mounting plate on door with two self-tapping / wood screws as 

shown     

     in             . 

7) Loosen adjustment nuts on mounting plate and Slide the sensor mounting plate towards the lock edge of 
the door so that there is no more than 3/8"-7/16" gap between the sensor mounting plate & the lock edge as  
shown in            . 

8) Line up the cover screws of the sensor cover with 

the slots provided on the sensor mounting plate. Adjust the sensor cover as needed. Attach sensor cover 
to the mounting plate and loosely tighten the cover screw provided as shown            . (Make sure the top 
of the cover extends no more than 1/8” above the top of the door). 

Test the operation of the sensor.

PULL SIDE OF THE DOOR

Telescoping Sensor

INS SSS-SEDA v6.0.vsd  Created: 9/23/2009 Revised:5/27/2010

                Page 2

¾”

Horizontal L

ine

Door

Top edge of the door

Frame

Frame

1-1/8"

Not
che
d e

dge 
of

 the 

Hin
ge

Fig-1

Fig-2

Fig-1

Fig-2

Fig-3

Fig-3

Pilot Hole

Fig-4

Fig-4

Sensor Mounting Plate

First Mounting Hole

Door

Door

Self – Tapping / Wood 

Screws

Sensor Mounting Plate

Fig-5

Fig-5

Wiring Hole

3/8"-

7/16"

Door

Loc

k Edge of

 the Door

Fig-5

Slot Provided

Door

Cover screw

Sensor Cover

Fig-6

Fig-6