2
Intent of Use
The Genesis® nG tool must
“only” be used for placing 3/16” & 1/4” NeoBolt® as outlined in “Tool setting guide – Small diameter
NeoBolt®:
(
07900-01071 GB)
Tool Specification
Air Pressure
Minimum - Maximum
5-7 bar
Free Air Volume Required
@ 5.5 bar
4.3 litres
Stroke
Minimum - Maximum
10-29 mm
Pull Force
@ 5.5 bar
12.9 kN
Cycle Time
Approximately
0.8 seconds
Noise Level
Less than
75 dB(A)
Weight
Without nose equipment
2.3 kg
Vibration
Less than
2.5 m/s2
Safety Instructions
For the full safety instructions refer to the associated Genesis® nG tool manual (
07900-00930 GB
)
Certificate of Conformity
Refer to the associated Genesis® nG Instruction Manual (
07900-00930 GB
)