Intent of Use 

 
The Genesis® nG tool must 

“only” be used for placing 3/16” & 1/4” NeoBolt® as outlined in “Tool setting guide – Small diameter 

NeoBolt®:

 (

07900-01071 GB) 

 

Tool Specification 

 

Air Pressure 

Minimum - Maximum 

5-7 bar 

Free Air Volume Required 

@ 5.5 bar 

4.3 litres 

Stroke  

Minimum - Maximum 

10-29 mm 

Pull Force  

@ 5.5 bar  

12.9 kN 

Cycle Time  

Approximately  

0.8 seconds 

Noise Level  

Less than 

75 dB(A) 

Weight  

Without nose equipment  

2.3 kg 

Vibration  

Less than  

2.5 m/s2 

 

Safety Instructions 

 
For the full safety instructions refer to the associated Genesis® nG tool manual (

07900-00930 GB

)

 

  

Certificate of Conformity 

 
Refer to the associated Genesis® nG Instruction Manual (

07900-00930 GB

)

 

 