SEE FIG. 16
Withdraw Photo Electric Cell from the burner head. Clean
PEC sensing end with a soft cloth taking care not to
scratch the light sensitive body. Re-insert PEC taking care
to insert the correct way round.
Should the cell show signs of distortion or cracking,
replacement will be necessary. See ‘PEC Replacement’ -
Page 17.
SEE FIG. 17
1.
Remove pozi screws, pull off fan case inlet.
2.
Clean between the blades of the fan impellor with a
small brush and remove any residue.
Re-assemble the burner in reverse order.
NOTE:
Burner head gaskets should be renewed at each
service.