desired pressure has been reached, release the Button and wait two seconds. The digital display will flash the new selected pressure,  

as in the following example:

  This pressure value is now stored in the unit’s memory until it is manually reset.

 5. Press the Power Button once more to begin inflation. The digital display will only show the current pressure of the object (which will 

light solid) to indicate that the compressor is working. Monitor the pressure on the LCD screen.

 6. When desired pre-set pressure is reached, the compressor will stop automatically. Press and hold the Power Button for one second to 

turn off the unit.

 7. Unscrew and remove the SureFit

®

 nozzle from the valve stem.

IMPORTANT AUTO MODE OPERATING NOTES: 

• To interrupt the inflation process, press the Power Button once. To resume the inflation process, press the Power Button again.

• To switch to Manual Mode, press the Power Button once to stop the inflation process, then press the Compressor Trigger. (The unit 

cannot switch to the Manual Mode while it is inflating.) 

• To shut down the unit at any time, press and hold the Power Button for one second.

• To select a new pressure value, press the Power Button once, then press the Increase (+) or Decrease (–) Pressure Control Buttons and 

resume the inflation process at step 5.

• After pressing the Power Button at any time during operation, the unit will automatically shut down after one minute if no further 

actions are taken.

Inflating Tires or Products with Valve Stems in Manual Mode

In the Manual mode, the Compressor Trigger on the front of the unit is used to operate the compressor until the desired pressure value is 

reached.

 1. Make sure all charging adapters are disconnected.

 2. Screw the SureFit

®

 nozzle onto the valve stem. Do not overtighten.

 3. Press the Power Button to turn the unit on. The backlit LCD Screen will display the following, indicating the unit is in Standby Mode:

  The digital display will alternately show the flashing pre-set PSI value (that was last set by the Pressure Control Buttons) for 2 seconds; 

then it will flash the current pressure of the item being inflated for 5 seconds (which will then light solid).

 

IMPORTANT: 

If no other actions are taken after pressing the Power Button, the unit will automatically shut off after one minute of 

inactivity.

 4. Press the Compressor Trigger to begin the inflation process. The digital display will only show the current pressure of the object (which 

will light solid, as in the following example) to indicate that the compressor is working. Monitor the pressure on the LCD screen.

 5. When the desired pressure is reached, release off the Compressor Trigger and the compressor will stop. Press and hold the Power 

Button for one second to turn off the unit.

 6. Unscrew and remove the SureFit

®

 nozzle from the valve stem.

IMPORTANT MANUAL MODE OPERATING NOTES: 

• To interrupt the inflation process, release the Compressor Trigger. To resume the inflation process, press the Compressor Trigger again.

• To switch to Auto Mode, release the Compressor Trigger, then press the Increase (+) or Decrease (–) Pressure Control Buttons 

or

 the 

Power Button. (The unit cannot switch to the Auto Mode while it is inflating.) 

• To shut down the unit at any time, press and hold the Power Button for one second.

• In this mode, the unit will automatically shut down after one minute of inactivity.

Inflating Other Inflatables Without Valve Stems

Inflation of other items requires use of the nozzle adapter.

 1. Make sure all charging adapters are disconnected. 

 2. Screw the nozzle adapter into the SureFit

®

 nozzle. Do not overtighten.

 3. Insert the nozzle adapter into item to be inflated.

Summary of Contents for AirPro 120 HRC120DS

Page 1: ...a intercambios solamente por lo general 30 a 90 días después de la fecha de compra La prueba de compra puede ser requerida por el minorista Por favor consulte la póliza de devoluciones del minorista sobre devoluciones que están fuera del plazo establecido para intercambios Esta garantía no se aplica a los accesorios bombillos fusibles y baterías defectos a consecuencias de desgaste normal accident...

Page 2: ...ANUAL AIRPRO120 COMPRESORRECARGABLE CONMANÓMETRODIGITAL MANUAL DE INSTRUCCIÓN SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE CONSERVE ESTE MANUAL PARA FUTURAS CONSULTAS 2017 Baccus Global LLC Boca Raton FL 33432 877 571 2391 HRC120DS HRC120DSG English page 4 Español pagina 10 x BC ...

Page 3: ...2 FEATURES CARACTERÍSTICAS 1 7 6 8 1 4 3 12 13 14 13 15 14 16 2 5 9 10 11 6 7 8 ...

Page 4: ...as de la FCC Estos límites están diseñados para brindar protección razonable contra interferencia perjudicial en una instalación residencial Este equipo genera usa y puede irradiar energía en frecuencia de radio y si no se instala y se usa de acuerdo con las instrucciones puede provocar interferencia perjudicial en las comunicaciones de radio Sin embargo no hay garantía de que la interferencia no ...

Page 5: ...n not in use and when charging Use of accessories and attachments The use of any accessory or attachment not recommended for use with this unit could be hazardous Refer to the accessory section of this manual for further details Stay alert Use common sense Do not operate this unit when you are tired or impaired Check for damaged parts Any part that is damaged should be replaced by the manufacturer...

Page 6: ...oltage protection may activate the empty battery icon will flash for a short period before automatic shut down If the unit shuts down it MUST be recharged immediately An empty battery icon indicates the battery MUST be recharged immediately Notes This unit is delivered in a partially charged state you must fully charge it upon purchase and before using it for the first time Initial AC charge shoul...

Page 7: ...minutes before returning to normal operation This feature protects the unit from overheating during normal use In any event do not operate the compressor continuously for extended periods of time approximately 10 minutes depending on ambient temperatures as it may overheat This could damage the compressor If the compressor must be operated for longer periods every 10 minutes press and hold the Pow...

Page 8: ... SureFit nozzle onto the valve stem Do not overtighten 3 Press the Power Button to turn the unit on The backlit LCD Screen will display the following indicating the unit is in Standby Mode The digital display will alternately show the flashing pre set PSI value that was last set by the Pressure Control Buttons for 2 seconds then it will flash the current pressure of the item being inflated for 5 s...

Page 9: ... When the unit is not in use we recommend that the battery is charged at least every 30 days Never submerge the unit in water If the unit gets dirty gently clean the outer surfaces of the unit with a soft cloth moistened with a mild solution of water and detergent There are no user replaceable parts Periodically inspect the condition of adapters connectors and wires Contact manufacturer to replace...

Page 10: ...D WARRANTY The manufacturer warrants this product against defects in materials and workmanship for a period of ONE 1 YEAR from the date of retail purchase by the original end user purchaser Warranty Period If there is a defect and a valid claim is received within the Warranty Period the defective product can be replaced or repaired in the following ways 1 Return the product to the manufacturer for...

Page 11: ...rabajo Guarde la unidad inactiva en el interior Cuando no está en uso esta unidad se debe almacenar bajo techo en un lugar seco alto o asegurada fuera del alcance de los niños Desconecte la unidad Desconecte la unidad de la alimentación eléctrica cuando no esté en uso y durante la carga Uso de accesorios y suplementos El uso de accesorios o dispositivos no recomendados para utilizar con este apara...

Page 12: ...plomo ácido requieren mantenimiento de rutina para asegurar una carga completa y una mayor duración de la batería Todas las baterías pierden energía por descarga espontánea se descargan con el paso del tiempo y con mayor rapidez cuando están a temperaturas más altas Por lo tanto las baterías necesitan ser cargadas periódicamente para reemplazar la energía perdida por descarga espontánea Cuando la ...

Page 13: ...va a seguir cambiando de hueco a sólido abajo a arriba pero no se mostrará 4 barras sólidas cuando se utiliza el método de carga de CC de 12 voltios Fabricante sugiere que sólo utilice el adaptador de carga de 12 voltios CC si la unidad necesita ser cargado inmediatamente y hay ninguna 120 voltios CA está disponible 4 Cobrar por 5 horas No sobrecargue 5 Desconecte el adaptador de carga de CC de la...

Page 14: ...la presión deseada suelte el botón y espere dos segundos La pantalla digital parpadeará la nueva presión seleccionada como en el siguiente ejemplo Este valor de presión ya está guardado en la memoria de la unidad hasta que se restablece manualmente 5 Pulse el botón de alimentación una vez más para comenzar la inflación La pantalla digital sólo mostrará la presión actual del objeto que se iluminará...

Page 15: ...lla en la boquilla SureFit No apriete demasiado 3 Inserte el adaptador en el artículo a ser inflado 4 Pulse el botón de alimentación para encender la unidad La pantalla LCD mostrará el siguiente mensaje que indica que la unidad está en modo de espera La pantalla digital parpadea alternativamente el pre ajustada valor que se estableció última por los botones de control de la presión durante 2 segun...

Page 16: ...acto y el fusible 3 Inspeccione el fusible con un control de continuidad 4 En caso de estar quemado busque un fusible de reemplazo de 12 amperios 5 Coloque el fusible el resorte de contacto y el cobertor posterior 6 Atornille la tapa trasera en sentido de las manecillas del reloj hasta que esté apretado NO LO APRIETE DEMASIADO 7 Asegúrese que el adaptador de carga CC esté funcionado de forma corre...

Reviews: