EX5210R Exciter Installation & Configuration Guide
19
4.
The Termination Switch of the Primary Exciter and the last Chained Exciter
in the chain must be set to On (o-o).
On the other Chained Exciters, it must be set to Off (-o o-).
5.
The Primary/Chaining configuration is set via AeroScout Engine Manager.
Chained Exciters inherit the Primary Exciter ID and LF configuration
.
Transmission range is configurable.
See Configuring Chained Exciters.
Configuring Chained Exciters
Each Chained Exciter must be set as ‘Slave Exciter’ and the transmission range
configured, in the AeroScout Engine Manager, before being connected to the
Primary.
The EX5210R appears as an
EX5210
in the Engine Manager
.
Configurations for Engine 5.2 and below
1.
Connect the Chained Exciter directly to the network via the LAN port.
2.
Under
IP Configuration
, check
Connected to network
.
3.
Configure the following parameters:
•
Transmission Range
(Internal LF Exciter > Settings tab): Select the
desired
transmission range
of the Chained Exciter so that the LF
coverage is sufficient and some overlap exists between the chained
Exciters.