CONVERSION 

 

Instructions are for conversion from Natural Gas to Propane (L.P.) on all models HMG. 

 

The conversion should be done before connecting the unit to the gas supply. 

 

Units are shipped from the factory equipped for use on natural gas. Orifices necessary for LP (propane) are 
provided in a bag tied to the valve on the front panel. 
1.  Remove the knobs and front panel. 
2.  Remove  the  orifice  fittings  from  the  valve.  Change  the  orifices  to  the  size  recommended  for  propane 

(L.P.). 

3.  Replace the orifice fittings into the valve. 

 

To change the regulator: 

 

 

Connect the regulator to the unit, connect gas and check for leaks. 

WARNING:

 Do not use an open flame 

to check for leaks. 

 

Check the system pressure. With the front panel removed remove the plug 
from the manifold. 

 

Place a fitting in the plug opening and connect a manometer. 

 

For  Natural  gas  the  pressure  in  the  manifold  should  be  5"  water  column  or  
12.4 millibar. For LP  the pressure in  the manifold should  be  10"  water Column of 
24.9 millibar. 

 

To adjust the pressure remove the brass cap and turn the white plastic part inside the stem of the regulator. 
See picture regulator 8. 

 

Take a wide straight screw driver and place it in the two notches shown in picture regulator 7 turn clockwise 
to increase pressure and counter-clockwise to reduce pressure. See picture regulator 8. 

 

Once the pressure has been adjusted replace the brass cap. 

 

Note  the  blue  cap  on  the  regulator,  this  is  the  vent  there  are  openings  below  the  top  rim. 

NEVER

  block 

these openings your regulator will fail to operate correctly. On a monthly basis blow off any dust or grease 

Summary of Contents for Tri-Star TSHMG-2424i

Page 1: ...not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause prop...

Page 2: ...uids in the vicinity of this or any other appliance Keep the area free and clear of combustibles See ANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in a pro...

Page 3: ...eration is fully trained and is aware of all precautions Accidents problems can result by a failure to follow fundamental rules and precautions The following words and symbols found in this manual ale...

Page 4: ...Do not slide unit with legs mounted lift if necessary to move unit Pipe threading compound must be resistant to the action of liquefied petroleum gases Caution DO NOT use an open flame to check for l...

Page 5: ...37 392 1 4 32 000 9 78 128 000 37 5 5 12 4 TSHMG 2460i 59 844 1520 0 24 609 6 15 437 392 1 5 32 000 9 78 160 000 46 9 5 12 4 TSHMG 2472i 71 844 1824 8 24 609 6 15 437 392 1 6 32 000 9 78 192 000 56 3...

Page 6: ...With the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold should be 5 water column or 12 4...

Page 7: ...7 which may accumulate around this cap The openings must remain open for the regulator to function Clean more often in a very greasy atmosphere...

Page 8: ...rates and light the pilot from above 4 Turn the manual shut off valve on 5 Hold an ignition source match to both openings on the pilot tube When the flames are established remove the ignition source 6...

Page 9: ...act as the heart of the ventilating system for the room or area in which the unit is installed and will leave the unit independent of changing draft conditions All valves must be checked and lubricate...

Page 10: ...oved After removal of the detergent the surface of the plate should then be covered with a thin film of oil to prevent rusting Clean stainless surfaces with a damp cloth and polish with a soft dry clo...

Page 11: ...ing into steam Food sticks to griddle Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges...

Page 12: ...22241494 Weldm t Griddle Plate 1 22241614 Weldm t Griddle Plate 1 22241734 Weldm t Griddle Plate 1 2 21826433 Side Firebox 2 2 2 2 2 3 21826022 Body 24 Firebox 1 21826122 Body 36 Firebox 1 21826222 Bo...

Page 13: ...21826652 Panel Back 36 1 21826252 Panel Back 48 1 21826332 Panel Back 60 1 21826452 Panel Back 72 1 20 22241253 Panel Control 24 1 22241373 Panel Control 36 1 22241493 Panel Control 48 1 22241613 Pan...

Page 14: ...21826036 Body 24 Firebox 1 21826136 Body 36 Firebox 1 21826236 Body 48 Firebox 1 21826336 Body 60 Firebox 1 21826436 Body 72 Firebox 1 4 21826017 Support Bumer 2 21826117 Support Bumer 2 21826217 Supp...

Page 15: ...ft 2 3 4 5 6 25 8633700 Leg 2 Dia Hvy Dty 4 4 4 4 4 26 2065839 Adapter 15 Angle Elbow 2 3 4 5 6 27 22400003 Brace Leg 2 2 2 2 2 28 21826134 Channel Stiffiner NA 1 21826234 Channel Stiffiner 1 21826334...

Page 16: ...16 NOTES...

Page 17: ...17 NOTES...

Page 18: ...AR shall bear the normal labor charges for repair of replacement to the extent that such repair or replacement is performed within 35 miles of the office of an authorized service agency within the con...

Reviews: