background image

 

 

MS350 - Manual

 

 

AM150B 

Standby AB – standbygroup.se 

MS350 

Thank you for choosing a product from Standby. 

Technical Data 

Description 

Units 

Dimensions 

44.6 mm x 136.1 mm x 131 mm 

Weight 

Approx. 400 g 

Nominal voltage 

12 / 24 VDC 

Operating voltage 

10,8 to 14.4 VDC / 21.6 to 28.8 VDC 

Limit voltage 

-32 to + 32 VDC 

Current consumption 

< 500μA at standby mode 

Inputs 

7 x < 20mA, active high 
1 x < 20mA, active low 

Outputs 

2 x < 6A 
4 x < 2A 

Enclosure rating 

IP 54 

Approvals 
- Accoustic 
- EMC 

 
T046Lu (Swedish approval, only valid together with two KSR350 4Ω(12V)/16Ω(24V) ) 
ECE R10 

Included 

Installation 

 

The Control-Unit can be installed as desired in the vehicle interior. Due to the housing design, the 
Control-Unit can be variably attached and connected to the vehicle with four screws. Care must be 
taken to ensure good accessibility of the connectors. 

Summary of Contents for MS350

Page 1: ...t consumption 500μA at standby mode Inputs 7 x 20mA active high 1 x 20mA active low Outputs 2 x 6A 4 x 2A Enclosure rating IP 54 Approvals Accoustic EMC T046Lu Swedish approval only valid together with two KSR350 4Ω 12V 16Ω 24V ECE R10 Included Installation The Control Unit can be installed as desired in the vehicle interior Due to the housing design the Control Unit can be variably attached and c...

Page 2: ...d be fused with max 1A Pin 3 and 4 S13 and S14 should together be fused max 15A fuse Connector P2 SUB D 15P Female Recommended metal hood MH Connectors MHDTZK15 K Recommended crimp socket Molex FL15S7 K121 Recommended crimp contacts Molex 1731120432 20 24 AWG Pin Function Standby Name 1 Output for external devices Y21 2 PA microphone PTT X22 3 PA microphone signal high 4mV X23 4 PA microphone shie...

Page 3: ...Not used set to off 5 Not used set to off 6 Not used set to off BCD Wheel Turn wheel to choose presets for selected country Pos 0 CAN This position is used when the amplifier is connected to a CAN based control system from Standby The connected control system sets the functionality of the amplifier Please see the description for the control system regarding functionality and connection ...

Page 4: ...ound will automatically be deactivated after 10 seconds Input X117 or X119 must be active to be able to use this function X113 20 mA max 1A 14 Ground MS 350 S114 10A 15 Yelp SE horn signal edge trigged Activate deactivate the sound The sound will automatically be deactivated after 10 seconds Input X117 or X119 must be active to be able to use this function X115 20 mA max 1A 16 Power Supply Amplifi...

Page 5: ...p US horn signal edge trigged Activate deactivate the sound The sound will automatically be deactivated after 10 seconds Input X117 must be active to be able to use this function X113 20 mA max 1A 14 Ground MS 350 S114 10A 15 Yelp US horn signal edge trigged Activate deactivate the sound The sound will automatically be deactivated after 10 seconds Input X117 must be active to be able to use this f...

Page 6: ...Hi Lo clean SE will be played for 2 cycles When activating more than one sound at the same time this input is used to change to next sound manually X115 20 mA max 1A 16 Power Supply Amplifier S116 10A 10A 17 Hi Lo clean SE continuous feed Activates the sound AND the output Beacon This input has higher priority than X119 and X121 if activated at the same time X117 20 mA max 1A 18 Beacon continuous ...

Page 7: ...und Yelp SE will be played for 20 cycles When activating more than one sound at the same time this input is used to change to next sound manually X115 20 mA max 1A 16 Power Supply Amplifier S116 10A 10A 17 Hi Lo clean SE continuous feed Activates the sound AND the output Beacon This input has higher priority than X119 and X121 if activated at the same time X117 20 mA max 1A 18 Beacon continuous fe...

Page 8: ...ble products www standbygroup se Standby will not be held liable for improper installation or use of this product Please follow all instructions provided Professional advice and proper installation of the Standby products by an authorized Standby Partner are recommended to provide maximum safety and function ...